ALUZ A8-ZIZA-TAPE Manuel d'instructions d'installation - Page 3
Parcourez en ligne ou téléchargez le pdf Manuel d'instructions d'installation pour {nom_de_la_catégorie} ALUZ A8-ZIZA-TAPE. ALUZ A8-ZIZA-TAPE 11 pages. Led tape
Également pour ALUZ A8-ZIZA-TAPE : Manuel (14 pages)
ZIZA
Tape
A8-ZIZA-TAPE
DIAGRAM OF DRIVER
Figure 1
FIGURE 1 (INPUT)
FIGURE 2 (INTERFACE)
Neutral (Blue)
Line / Hot (Brown)
Ground (Green)
DALI+
DALI-
DALI+
DALI-
Mode
TYPICAL DAISY CHAIN LAYOUT (DMX STATIC COLOR)
Neutral (Blue)
Line / Hot (Brown)
Ground (Green)
Neutral (Blue)
Line / Hot (Brown)
Ground (Green)
NOTES (DMX)
• Default DMX address of each luminaire is 001. Consult third party DMX
commissioner to modify at time of installation. ALUZ does not provide DMX
commissioning.
• DMX Address must be set for each driver. Default DMX address for each driver is 001.
• A DMX Control System (by others) must be used to operate the system.
• The last driver in a daisy chain sequence must be terminated.
• Up to 28 drivers may be daisy chained together using shielded cable specifi ed for
DMX wiring.
• Wire colors on diagram correspond to colors of driver terminals.
• Driver load not to exceed 96W.
It is recommended to only load drivers to 80% for best dimming performance.
• Ensure DIP Switch 1 is set to ON (Left) to activate 24V operation.
Figure 2
Control Interface
(-)
(+)
DMX Input
(from control system, by others)
DMX+
DMX-
DMX Ground / Shield
Common +
Channel 1 -
J-Box (by others)
DMX+
DMX-
DMX Ground / Shield
Common +
Channel 1 -
J-Box (by others)
DMX+
DMX-
DMX Ground / Shield
DMX Output
(to next driver, if applicable)
ALUZ
1170 North Red Gum Street, Anaheim, CA 92806
Phone: 800 921 2254 or 714 535 7900 | Fax: 714 535 7902 | [email protected] | aluz.lighting
© ALUZ All rights reserved. ALUZ reserves the right to make changes or withdraw specifi cations without prior notice.
Dimming Protocol & Wiring Diagrams (DMX & DALI Driver - DRV100-E)
Figure 3
FIGURE 3 (DMX OUTPUT)
DMX+ Input
DMX- Input
DMX Ground / Shield Input
DMX+ Output
DMX- Output
DMX Ground / Shield Output
EXT+ Input
EXT- Input
DIP Switch 1
(Set to left for 24V)
Not Used
TYPICAL DAISY CHAIN LAYOUT (DALI STATIC COLOR)
DALI Input (from control system, by others)
Ground (Green)
Neutral (Blue)
Line / Hot (Brown)
LED Lighting
LED Lighting
DALI+
DALI-
Ground (Green)
LED Lighting
Neutral (Blue)
Line / Hot (Brown)
LED Lighting
LED Lighting
DALI+
DALI-
DALI Output
LED Lighting
(to next driver, if applicable)
NOTES (DALI)
• DALI commissioning to be performed by a third party at time of installation.
ALUZ does not provide DALI commissioning.
• Wire colors on diagram correspond to colors of driver terminals.
• Driver load not to exceed 100W.
It is recommended to only load drivers to 80% for best dimming performance.
• A DALI Control System (by others) must be used to operate the drivers.
• Ensure DIP Switch 1 is set to ON (Left) to activate 24V operation.
• DALI Address must be set for each driver.
• Up to 28 drivers may be daisy chained together using shielded cable specifi ed for
DALI wiring.
FIGURE 4 (DALI OUTPUT)
Not Used
Not Used
Not Used
Common (+)
Not Used
Channel 1 (- / Red)
Not Used
Channel 2 (Green)
Not Used
Channel 3 (Blue)
EXT+ Input
Channel 4 (White)
EXT- Input
DIP Switch 1
(Set to left for 24V)
DALI+
DALI-
Installation Instructions
9 / 1 / 2021 / Rev 0
Page 3 of 11
Common (+)
Channel 1 (-)
Not Used
Not Used
Not Used
Not Used
Common +
V+
LED Lighting
Channel 1 -
V-
Common +
V+
LED Lighting
Channel 1 -
V-