STEP 11 . ALERT & ERROR LIST
When an error or alert popups on the screen, check in the description below to
know how to deal with it :
N°
TYPE
#100
ERROR
BOOTLOADER
#101
ERROR
BOOTLOADER
& FIRMWARE
#102
ERROR
FIRMWARE
#103
ERROR
FIRMWARE
#104
ERROR
FIRMWARE
#105
ERROR
FIRMWARE
#106
ERROR
FIRMWARE
#107
ALERT
#108
ALERT
VS (version)
DESCRIPTION & SOLUTION
1.0.0
Press the rotary encoder
Update the firmware
1.0.0
EEPROM not responding
1.0.0
Reboot the device
1.0.0
SRAM not responding
Reboot the device
1.0.0
SDP not responding
Reboot the device
Tachymeter not responding
1.0.0
Fan working but the screen displays 0 RPM
Contact the Alveo3D technic support
1.0.0
Low pressure (small airdrop)
Check if the filter is well positioned
1.0.0
High pressure (PWM:10% & PDIFF>80Pa)
Too much air drop (displayed if fan speed : 10%)
Check nothing block the airflow to the filter
in the hose or between the filter and fan
1.0.0
Filter saturation high ( >= 90% )
Monitor the filter replacement time
1.0.0
Filter saturation very high ( >= 98% )
Change the filter
15