AMC XG Petunjuk Pemasangan dan Pengoperasian Manual - Halaman 10

Jelajahi secara online atau unduh pdf Petunjuk Pemasangan dan Pengoperasian Manual untuk Penguat AMC XG. AMC XG 13 halaman. 16 channel

AMC XG Petunjuk Pemasangan dan Pengoperasian Manual
APPENDIX I - SERIAL COMMUNICATION
SPECIFICATIONS
HARDWARE SPECIFICATION
*RS232 asynchronous serial
communication
*9600 bps, 8 bits, 1 stop bit, no parity
*no flow control
SOFTWARE SPECIFICATION
Full command format:
Full command format is based on human
readable ASCII characters. All codes are
separated with field separators and
terminated by line terminator.
field separator
separator for fields in the command line
one or more spaces
line terminator
terminator for the command line
CR, LF, CR/LF, or LF/CR
COMMAND REFERENCE
Power On/Off
Turn Power On:
POWER ON<CR>
Turn Power Off:
POWER OFF<CR>
Read Power Status:
POWER<CR>
RETURN: "ON" or "OFF"
Power Toggle:
POWER TOGGLE<CR>
System Commands
Display unit identity:
Display the brand name of this unit:
BRAND<CR>
Display the model name of this unit:
MODEL<CR>
Display the current version of the
firmware:
VERSION<CR>
Reset unit:
Reset and reboot the system by
issuing the following
RESET<CR>
Restore to factory default:
To restore all "Setup" values to factory
default:
FACTORY<CR>
Enter firmware upgrade mode:
To enter firmware upgrade mode:
FIRMWARE<CR>
After software upgrade mode is entered,
the firmware upgrade software needs to be
executed from a PC or supplied upgrade
system in order to start the upgrade
process.
Enter test mode:
To enter test mode:
TEST<CR>
command: