Baumer Hubner Berlin microGen PMG10 EtherNet/IP Panduan Pengoperasian - Halaman 20
Jelajahi secara online atau unduh pdf Panduan Pengoperasian untuk Konverter Media Baumer Hubner Berlin microGen PMG10 EtherNet/IP. Baumer Hubner Berlin microGen PMG10 EtherNet/IP 40 halaman. Absolute encoder
6
|
Electrical installation
6.1
EtherNet/IP
INFO
Use only supply cables and connectors compliant to the EtherNet/IP guideline.
6.1.1
Features EtherNet/IP
INFO
Detailed instructions for the EtherNet/IP interface as well as the XML file can be found on the
Baumer website www.baumer.com.
Fieldbus protocol
Device profile
Features
Process data
6.1.2
Pin assignment EtherNet/IP
Ill. 9: Terminals PMG10 EtherNet/IP
1
Male connector (4-pin, A-encoding)
3
Bus terminal box
20
1 2 2
Operating Manual
EtherNet/IP
Encoder Device, Type 22hex, according to CIP
specification
100 MBaud Fast Ethernet
Programmable IP address
Automatic IP address assignment (DHCP)
Direction of rotation, resolution, total resolution
and preset programmable according to CIP
specification
Position value, warning flag, alarm flag Assem-
bly Instances 1 and 2 according to CIP specifi-
cation
3
2
Mating connector (4-contact, D-encoding)
PMG10 & PMG10P EtherNet/IP | V1
Baumer Hübner