Baumer Hubner HMC16 Series Petunjuk Pemasangan dan Pengoperasian - Halaman 36

Jelajahi secara online atau unduh pdf Petunjuk Pemasangan dan Pengoperasian untuk Konverter Media Baumer Hubner HMC16 Series. Baumer Hubner HMC16 Series 44 halaman. Encoder without bearings - incremental

Baumer Hubner HMC16 Series Petunjuk Pemasangan dan Pengoperasian
FILTER DIAGRAMS HMCP16
8.7
Filter setting „12" (range 2 ms)
10
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
0
10
8.8
Filter setting „13" (range 4 ms)
10
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
0
10
32/40
Filter "12", group delay = 2119 μs
1
10
10
Frequency [Hz]
Filter "13", group delay = 4159 μs
1
10
10
Frequency [Hz]
2
3
10
2
3
10
MB168T1EN - 11184527, 19A2, Baumer_HMC16-T1_II_EN
4
10
4
10