Asus AP100 Panduan Referensi Perangkat Keras - Halaman 23

Jelajahi secara online atau unduh pdf Panduan Referensi Perangkat Keras untuk Server Asus AP100. Asus AP100 32 halaman. Pentium ii startup server

II. System Components

Hard Disk Drive Mounting

Two hard disk drives may be mounted into the 3.5" device cage, a single
hard disk drive may be mounted on top of the power supply, and two more
may be mounted in the 5.25" device cage using hard disk drive carriages
(not provided) designed for use in 5.25" device bays. The exception is
Quantum's Bigfoot IDE hard disk drive which fits in the 5.25" device bays.
CAUTION:
Adequate cooling cannot be made for high-speed SCSI hard
disk drives mounted in the 5.25" device cage, therefore it is not recommended.

Top of the Power Supply

A small hard disk drive carrier plate on top of the power supply is used to
hold a 1" hard disk drive. The underside of the hard disk drive mounts to the
bottom of the carrier plate. There is nothing else to fasten since the side
panel will hold the carrier plate in.
Hard disk drive mounted on carrier plate
Inserting or removing a hard disk drive on
top of the power supply
AP100 Hardware Reference Guide
Carrier slides into the
chassis in this direction
Handle faces upward
Hard disk drive carrier plate
1" (thick) hard disk drive
23