Baumer NE230 Panduan Petunjuk Pengoperasian - Halaman 41

Jelajahi secara online atau unduh pdf Panduan Petunjuk Pengoperasian untuk Penghitung Uang Tunai Baumer NE230. Baumer NE230 44 halaman. Electronic preset counter in din rail housing

Up and down count with
two counting signals by
90° out of phase
The counting direction is
automatically recognized
on the basis of the 90°
leading or trailing phase
shift. The internal phase
discriminator does the
evaluation.
Single, double or quadruple
evaluation is possible.
Programming line 25 to
digit 3, 4 or 5.
Programming
Operating mode:
Line 22 to 0 = Progres-
sive selection
Reset mode: Line 29 to 2
without automatic reset
Output time P1, P2:
Line 35, 36 to pulse or
duration
Operating mode:
Line 22 to 0 = Progres-
sive selection
Reset mode: Line 29 to 0
with automatic reset
Operating mode:
Line 22 to 1 = Main
preset
Reset mode: Line 29 to 0
with automatic reset
Track A
Track B
0
1
2
3
4
Counting
4x
0
1
2
Counting
2x
0
1
Counting
1x
8 Output responses (output mode)
The behavior of the signal outputs is defined by the following set-
tings under the programming field 3: Operating mode, reset mode,
take-over of preselections, output logic and output time P1, P2 as
momentary
or latched signal
The following diagrams illustrate some examples:
adding
RESE T
VW (P2)
VW (P1)
O (SC)
OU T P1
OU T P2
RESE T
VW (P2)
VW (P1)
O (SC)
OU T P1
OU T P2
RESE T
VW (P2)
VW (P1)
O
OU T P1
OU T P2
www.baumer.com
5
6 7 8
7
3
4
2
subtracting
RESE T
SC
VW (P1)
VW (P2)
OU T P1
OU T P2
RESE T
SC
VW (P1)
VW (P2)
OU T P1
OU T P2
RESE T
SC
VW (P2)
VW (P1)
O
OU T P1
OU T P2
NE230
6
5
4
3 2 1
0
3
2
1
0
1
0
signal.
41