Follett HCD1400RBT Manual - Halaman 7
Jelajahi secara online atau unduh pdf Manual untuk Pembuat Es Follett HCD1400RBT. Follett HCD1400RBT 8 halaman. With remote air-cooled condensing unit
Juga untuk Follett HCD1400RBT: Panduan Petunjuk Instalasi (17 halaman), Manual (8 halaman)
Horizon
Chewblet ice machine
Single phase
1000 Series – 32.0" (81 cm)
1400 Series – 31.4" (80 cm)
1650 Series – 31.4" (80 cm)
Condensing unit requirements/unit specifications
Single phase
HCD1000
models
Shipping weight
225 lbs
(102 kg)
Standard electrical
Voltage
208-230
Phase
1-phase
Hertz
60 cycles
Min. Circuit Amp 10.7
Maximum circuit
15 Amps
HVACR breaker
size
Three phase
HCF1000
models
Shipping weight
320 lbs
(145 kg)
Standard electrical
Voltage
208-230
Phase
3-phase
Hertz
60 cycles
Min. Circuit Amp 9.9
Maximum circuit
15 Amps
HVACR breaker
size
Side View
Three phase
26.4" (67 cm)
26.4" (67 cm)
26.1" (66 cm)
Single
phase
26.6"
(68 cm)
Three
phase
26.1"
(68 cm)
HCD1400
HCD1650
330 lbs
385 lbs
(150 kg)
(175 kg)
208-230
208-230
1-phase
1-phase
60 cycles
60 cycles
20.0
29.9
30 Amps
50 Amps
HCF1400
HCF1650
320 lbs
340 lbs
(145 kg)
(154 kg)
208-230
208-230
3-phase
3-phase
60 cycles
60 cycles
14.0
21.2
25 Amps
35 Amps
Follett Corporation
801 Church Lane • Easton, PA 18040, USA
+1 (610) 252-7301 • Fax +1 (610) 250-0696
www.follettice.com
1000 series 1400 series or 1650 series
with remote air-cooled condensing unit
Condensing unit requirements/unit specifications
Front View
Single phase – 40.7" (103 cm)
Three phase – 36.3" (92 cm)
Condensing unit operating limits
All models
Air temperature
Condensing unit location/installation limits
All Models
Maximum refrigerant line run length:
Maximum line rise above evaporator:
Evaporator mounting above condenser:
or maximum refrigeration line drop:
Cooling capacity for ice machines connected to
rack systems
Models
BTU/hr (Kcal/hr) at
0 F (-18 C)
evaporator, 90 F
(32 C) ambient air
(1000N, 1400N,
1650N units only)
Rack Systems* EPR
Value – set to
Condensing unit specification/installation notes:
1. 1400 and 1650 model condensing units have a liquid
suction line heat exchanger. The entire liquid line should
be insulated separately from the suction line.
2. Outdoor installation of low side is not recommended and
will void warranty.
* EPR valve to be supplied by installer
Follett Europe Polska Sp. z o.o.
Mokry Dwór 26C 83-021 Wiślina, Poland
+48 (58) 785-6140 • Fax +48 (58) 785-6159
www.folletteurope.com
Minimum
Maximum
-20 F (29 C)
120 F (49 C)
100 ft (30.5 m)
35 ft (10.7 m)
15 ft (4.6 m)
15 ft (4.6 m)
HCD1000
HCD1400
HCD1650
7,700
10,000
13,000
(1940)
(2520)
(3275)
0 F (-18 C)
Form# 3815
7