POSSIBLE CAUSE: The humidifier is not turning off when the
furnace is turning off.
REMEDY: See section above for solution. If the unit is running
when the furnace is not in heating mode then very little water will
be evaporated and most of the water will be going down the
drain.
POSSIBLE CAUSE: The unit is working properly and the furnace
is supplying the proper conditions – just not happy with the water
usage.
REMEDY: Flow thru humidifiers will use water – this unit has a
restrictor inline to keep the water usage to the minimum required
to achieve the rated output – based on testing this unit will use
totally approx. 37 US gallons of water in 24 hours of total
humidifier operation – if this is unacceptable for you, replace the
supplied self piercing water valve with a proper shut off valve and
back off the water supplied to the unit until the amount of water
being drained is acceptable for you.

PROBLEM: TOO MUCH HUMIDITY IN THE HOME

POSSIBLE CAUSE: Humidistat set too high.
REMEDY: Turn humidistat down.
POSSIBLE CAUSE: Humidistat not located in the proper position.
REMEDY: Locate the humidistat in a central location and adjust
accordingly.
POSSIBLE CAUSE: Secondary humidity sources.
REMEDY: Humidity levels vary greatly from home to home – the
time of year your home was built will affect the levels – the
amount of showers taken, cooking, the amount of ventilation a
home has, as well the amount of people living in a home will
affect the humidity level – turn the humidistat down or turn off
the humidifier until required.

PROBLEM: SOLENOID VALVE BUZZING OR HUMMING

POSSIBLE CAUSE: The 6" spring clamp used to hold the bypass
tube is touching the valve.
REMEDY: Adjust the position of the 6" spring clamp so the valve
does not buzz or hum.
POSSIBLE CAUSE: Loose screws holding the solenoid valve.
REMEDY: Tighten the two screws which hold the solenoid valve
in place.
POSSIBLE CAUSE: The humidifier body is not secured to the
furnace duct properly.
REMEDY: Ensure all 4 screws which hold the humidifier body in
place are installed and are tightened.
Model 5000/6000 Flow Through Humidifiers
POSSIBLE CAUSE: Using a copper water supply tube and the
water tube is touching some part of the furnace.
REMEDY: If using copper water tube ensure it is not touching
some part of the furnace – you may have to use cushioned pipe
clamps to stop humming or buzzing. We recommend that you
use the supplied plastic water supply tube.
POSSIBLE CAUSE: No water is present at the valve when
activated.
REMEDY:
• Ensure the water supply valve is open and supplying water to
the unit.
• Check that the water inlet filter is not plugged. Replace if
required. (Procedure on page 3)
• Check that the black orifice fitting is not plugged. (Procedure
on page 3)
POSSIBLE CAUSE: Water connection to the unit not properly
done.
REMEDY: Check your water connections at the self piercing valve
and to the humidifier's solenoid valve – ensure that the ends of
the plastic tube were sanded – ensure that you have installed all
the proper hardware (see section instructions - water supply
connection), ensure that you have not cross threaded the fittings
– you will have to replace them if you have.
POSSIBLE CAUSE: Flexible water supply tube to the humidifier's
distribution tray not installed.
REMEDY: After the installing the humidifier's evaporator pad
assembly into the unit and before putting the front cover on it is
important that you firmly install the flexible black tube into fitting
at the top of the distribution tray.
POSSIBLE CAUSE: Water supply tube has a leak.
REMEDY: The tube is in contact with a heat source or has been
pierced with a staple or nail – replace the tube as required –
regularly inspect the water supply tube and the water drain tube
for wear or leaks.
POSSIBLE CAUSE: Evaporator pad assembly is not installed
correctly.
REMEDY: Ensure that the evaporator pad assembly is installed as
per the instructions and that the bottom spout is allowing the
water to flow our of the unit via the drain fitting.

PROBLEM: LEAKING WATER