Electrolux ZUCA1 Panduan Pengguna - Halaman 5

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Mesin pencuci piring Electrolux ZUCA1. Electrolux ZUCA1 14 halaman.

Electrolux ZUCA1 Panduan Pengguna
B INSTRUCTIONS FOR THE INSTALLER/MAINTENANCE PERSON
Install a disconnecting switch with a capacity at
least equal to that given in the technical data table,
a 30mA residual current circuit breaker and an
overcurrent device (magnetothermal cut-out with
manual reset or fuse) between the appliance and
the mains power outlet.
The chosen device must be lockable in the open
position in case of maintenance.
RATING PLATE
The rating plate contains identification and technical
data and is located on the right-hand side panel of the
appliance (Figure 5).
Figure 5
B1
WATER CONNECTION
CAUTION
Watermark labelled machines must be installed in
accordance with AS/NZS 3500.1.
If the dishwasher is installed under a worktop, make
sure the dimensions of the space in which it is placed
match those given in Figure 6.
Figure 6
Position the dishwasher and level the appliance by
turning the relative height-adjustable feet (Figure 5).
If the dishwasher is installed on a suitable support (e.g.
worktop); proceed as follows:
-
Access the bottom of the machine and unscrew the
4 feet.
-
-
Model LS5
PNC 9CGX 400100 05 Ser.N .123000001
AC 400V 3N
50Hz
Power Boiler
16500w
Power Tank
7500w
Power Max
26800w
Made in EEC
Model RT10 ED
-
PNC
9CGX400100 05
Ser.N .123000001
Make four ø 9mm though holes in the support, res-
pecting distances given in Figure 7.
Figure 7
Place the dishwasher on the support, matching the
holes just made with the seats of the feet in the
bottom of the machine (Figure 8).
Secure the dishwasher with M8 screws.
Figure 8
Connect the appliance water supply pipe "A"
(Figure 4) to the mains, fitting a cut-off valve, the fil-
ter provided and a pressure gauge between the
appliance and the mains (Figure 9).
In NUC1G / EUC1G models, connect the double
non-return valve "B" (Figure 9) supplied and the
machine supply pipe.
!
B
Figure 9
Check that the dynamic water supply pressure,
measured between the appliance and the main, is
between 200 and 300 kPa for machines with pres-
sure boiler and between 50 and 700 kPa for
machines with atmospheric boiler (test while dish-
washer tank or boiler is filling with water).
If the pressure is too high, fit a suitable pres-
sure reducer on the inlet pipe.
431 mm
7