Andersen Verilock 0106512 Panduan Pengguna - Halaman 7
Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Sensor Keamanan Andersen Verilock 0106512. Andersen Verilock 0106512 16 halaman. For a-series and 400 series windows and patio doors, 200 series patio doors and renewal by andersen windows
Battery Replacement Instructions - continued
Renewal by Andersen Casement and Awning Windows
1. Move the window lock handle on the lower lock to
the center position. The sash can be open or closed.
2. Remove the lock handle with magnet.
3. Remove bezel cover first.
4. Remove the VeriLock sensor using a small flat blade
screwdriver to release the clips as shown. (VeriLock
sensor assembly is located on the left-hand lock
for awning windows - as viewed from the interior).
Remove the VeriLock sensor using a thin blade putty
knife, if needed, being careful not to damage the
sensor.
5. Carefully remove the battery cap.
6. Remove discharged battery from the VeriLock
sensor assembly using a small flat blade screwdriver
to carefully pry the battery from the terminal. (see
battery disposal information on page 5).
7. Replace the battery with (1) one fresh CR-2032
lithium coin cell battery with the positive (+) side
facing out as shown.
8. Reapply the battery cap.
9. Attach the bezel cover to the VeriLock sensor.
10. Reinstall the VeriLock sensor assembly making
sure the arrow on the face of the sensor is pointing
upward. Continue to fully push the assembly in (using
a thin blade putty knife to guide into cavity if needed).
The assembly will snap into place around the lock
when properly inserted.
8. Reinstall lock handle with magnet onto lock lever by
pushing handle onto lock until an audible snap can be
heard.
9. Verify the proper battery polarity by observing the
L.E.D. light illumination during the lock operation. If
the L.E.D. does not illuminate, check to make sure
Steps 7 - 10 were followed correctly and check to
make sure the magnet is positioned properly around
the lock handle as shown.
10. Close and lock the window unit.
11. Verify that the sensor is communicating with your
security system or self-monitoring application by
unlocking the window and checking for the unlocked
message and then open the window and checking for
the window open message.
9142268
Renewal by Andersen
Casement and Awning Windows
Lock Handle
with Magnet
Press bezel cover clip to
1
remove bezel cover first
(use a small flat blade
screwdriver if needed.)
Insert screwdriver
into slot end to
remove battery.
VeriLock
Sensor
Bezel
Cover
Attach bezel cover to
VeriLock sensor before
re-installing.
7
User's Guide
Lock
Lever
VeriLock
Sensor
Bezel
Cover
Press bezel carrier clip
2
through the routed
opening, with small flat
blade screwdriver, to
release the sensor.
Battery
Cap
CR-2032
Battery
VeriLock
Sensor