Atkinson Dynamics AD-28LD-MV Panduan Petunjuk Instalasi dan Servis - Halaman 6

Jelajahi secara online atau unduh pdf Panduan Petunjuk Instalasi dan Servis untuk Sistem interkom Atkinson Dynamics AD-28LD-MV. Atkinson Dynamics AD-28LD-MV 16 halaman.

J2
CLASS I WIRING
ISOLATED BALANCED/UNBALANCED LINES:
The audio signals are transmitted over a wire pair using balanced
line technology. This means each wire carries a signal that is opposite
in polarity of the other. At the input of the intercom is an isolated
balanced line transformer. This transformer subtracts the two signals
from each other providing an output free of noise generated onto the
wires by some other noise source such as a motor or light fixture near
the wires.
The isolation provided by the transformer means that the grounds
of the units are not connected by the audio lines. Therefore, ground
loops and other problems caused by non-isolated systems are avoided.
The polarity of the audio lines between the + and - signal terminals
need not be maintained.
A shielded cable can be used in installations where extreme
problems from interference are suspected. The shield should always
be connected to the ground of only one of the intercoms. Connecting
the shield to ground at both ends will cause ground currents to travel
through the shield which could cause hum in the system.
There are several diagrams in the back of the manual to aid in
wiring intercoms together. The wiring diagram section illustrates bal-
anced and unbalanced line interconnection along with how a shielded
audio cable can be used. (See figures 5 through 12.) It also illustrates
COMMON
PHASE
GROUND
24VDC IN/OUT
REMOTE CONTROL
REMOTE SPEAKER
CLASS II WIRING
Figure 3.
-6-
GROUND
+
-
EXT CALL
CONTACT
J7
290A3078