Atlantic ColorFalls CC12 Panduan Pengoperasian - Halaman 3
Jelajahi secara online atau unduh pdf Panduan Pengoperasian untuk Peralatan Rumput dan Taman Atlantic ColorFalls CC12. Atlantic ColorFalls CC12 14 halaman. Color changing colorfalls
Juga untuk Atlantic ColorFalls CC12: Panduan Pengoperasian (14 halaman)
Plumbing Modular Colorfalls
Connect the Colorfalls together using 1½" Schedule 40 PVC Pipe. The pipe stub
should be 1
3
/
" long, which will ensure that the weirs touch when glued together.
8
When gluing multiple Colorfalls together, make sure that it is done on a flat
surface, so the lips of the weirs line up perfectly (Figure 2). Secure the Colorfalls
together until the glue has set.
1½" Sch 40 pipe (1
Figure 2
Clean and Glue
When plumbing multiple Color Changing Colorfalls together, use the back center
inlet on each individual Colorfalls, plugging the side inlets, regardless if you are
using one pump or multiple pumps. This will balance the flow of water going to
the falls. The individ-
ual feed lines to each
Colorfalls should be
1½" PVC. If using one
pump to feed multiple
Colorfalls, the main
feed line should be
2" or larger. The main
feed line should be run
horizontally along the
back of the wall with
vertical 1½" feed lines
branching off to each
Colorfalls (Figure 3).
Figure 3
Operation
Technical Data (Control Module)
Working Temperature:
0ºF -140ºF (-20°C - 60ºC)
Output: 3 circuits (R/G/B)
4
3
/
" long)
8
1½"
1½"
2" Feed
Input Power: AC12V
Output Power: DC12V, <144W
Output Current: <4A /circuit
Installation Requirements
1. The Control Module is weather resistant with an IP54 rating. Do not submerse it
or expose it to heavy rainfall. It must be mounted off the ground close to the
power source. Failure to do so will void the warranty.
2. Ensure that all cable connections are secure.
3. Install the control box in a well ventilated area to ensure that the module
operates in within its working temperature specified above.
4. Verify that the control module input voltage is 12 volt AC. We recommend that
you use the transformer provided with this unit.
5. Do not connect the power before the cord connections are finished.
6. Do not cut or alter the cord between the Colorfalls and the Control Module.
7. The remote control requires three (3) AAA batteries (not included).
Connecting the Light Bar
Follow the connecting chart below to connect all cables. Ensure that the
unit is not plugged in while connecting.
LED Light Strip
Atlantic's CCCM05 Master Controller (sold separately) enables up to five individual
Color Changing light bars to be synchronized to change colors at the same time
using one remote. In this application, only one Control Module and one remote
are required. Use a Control Module and remote from any Colorfalls and it will
control all light bars when used with the CCCM05 Master Controller. Replace the
transformer from your Colorfalls with the 80 watt transformer from the Master
Controller, and connect the 5-Way splitter supplied with the CCCM05 between the
Control Module and the light bars. See the connecting chart below for details.
Lines
Control Module
LED Light Strip
Control Module
5-Way Splitter
Transformer
Transformer
5