Eco-Logic Unit Specifications / Equipment Installation Recommendations:
Model 4:
a) CFM of Unit:
b) Maximum PSI of Unit:
c) Maximum Depth of Pond:
d) Maximum Surface Area Size:
e) Physical Sizes of Unit:
f) Recommended Accessories:
Equipment Installation Recommendations:
1) Electrical Power Required:
Model 4:
2) Location Selection:
a) Units should be installed in a properly ventilated area.
b) The unit's front panel should be accessible as well as the lamp access cover for lamp removal.
c) Air intakes on the bottom of unit should be a minimum of 12" off the floor.
d) For wall mounting, select a vertical structure, which will support the unit.
e) Floor mounts should be bolted to a cement pad.
f) For outside installations, if possible, locate the unit out of direct sunlight, keep the unit away from
any sprinkler path and away from the green.
3) Installer:
a) Follow all local and state electrical codes to choose the correct wire size for length of run and wire
protection.
b) Review Guidelines of Aeration Tubing Installation located in this manual.
Eco-Logic Manual.doc
4 CFM
700 Watts or 6 Amps
15 PSI
34 Feet Deep
1 Acre or 43,560 Square Feet
36 1/4" x 12 1/8" x 18"
100 ft. of feeder tubing (270008)
250 ft. of 3" aeration tubing (270009)
(2) Plug connector (271525)
(1) Tee connector (271538)
(6) Hose clamps (271542)
8/12/2002