Atlas CP400 Panduan Pemilik - Halaman 8

Jelajahi secara online atau unduh pdf Panduan Pemilik untuk Penguat Atlas CP400. Atlas CP400 16 halaman. Commercial dual channel power amplifiers
Juga untuk Atlas CP400: Panduan Pemilik (16 halaman), Brosur & Spesifikasi (10 halaman), Panduan Pemilik (16 halaman)

Atlas CP400 Panduan Pemilik
CP700
Commercial Power Amplifier
CP400 & CP700 COMMERCIAL
POWER AMPLIFIER
unbalanced Input
Unbalanced wiring typically is found on consumer equipment (CD players, DVD players, etc.) and is
generally a compromise of noise rejection and cable lengths. A single conductor and an overall shield
are most common, as in the standard cables supplied with consumer equipment. Keep unbalanced wire
lengths within 10' between equipment, wire the hot lead to the "+" terminal, and the shield to the ground
terminal. Install a jumper wire between the "-" terminal and the ground – a loss of gain will result without
this jumper (Figure 4).
GND
1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. •
©2008 ATLAS SOUND LP
White/Red (+)
Shield
IN
AMPLIFIER INPUTS
CH-2
+
-
GND
THRU
LEVEL
Specifications are subject to change without notice
AtlasSound.com
Printed in U.S.A.
POWER
White/Red (+)
Shield
CH-1
-
+
THRU
LEVEL
STEREO
PARALLEL
BRIDGE
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
TELEPHONE: (800) 876-3333 • FAX: (800) 765-3435
OWNER'S MANUAL
IN
Jumper
Figure 4
ATS002102 RevD 2/08
PP