Atlas Copco LCD 1500 Manual Petunjuk Keselamatan dan Pengoperasian - Halaman 13

Jelajahi secara online atau unduh pdf Manual Petunjuk Keselamatan dan Pengoperasian untuk Bor Atlas Copco LCD 1500. Atlas Copco LCD 1500 20 halaman. Hydraulic core drill

Atlas Copco LCD 1500 Manual Petunjuk Keselamatan dan Pengoperasian
LCD 500, 1500
cause overheating and cause foreign matter to enter
the hydraulic system.

Hydraulic oil

In order to protect the environment, use of biologically
degradable hydraulic oil is recommended. No other
fluids must be used.
Viscosity (preferred) 20-40 cSt.
Viscosity (permitted) 15-100 cSt.
Viscosity index minimum 100.
Standard mineral or synthetic oil can be used. Make
sure to only use clean oil and filling equipment.
When the machine is used continuously, the oil
temperature will stabilise at a level which is called
the working temperature. This will, depending on the
type of work and the cooling capacity of the hydraulic
system, be between 20-40°C (68-104°F) above the
ambient temperature. At working temperature, the
oil viscosity must be within the preferred limits. The
viscosity index indicates the connection between
viscosity and temperature. A high viscosity is
therefore preferred, because the oil can then be used
within a wider temperature range. The machine must
not be used, if oil viscosity fails to remain within the
permitted area, or if the working temperature of the
oil does not fall between 20°C (68°F) and 70°C
(158°F).

Pressure adjustment

The maximum pressure of the power source is
important. The pressure created in case of an
incorrectly or unfitted return line coupling would
cause overloading. Which could harm the machine
and result in bodily injuries. The maximum pressure
of the power source is 172 bar (limited by safety
valve adjustment).
WARNING Operating pressure
If the maximum operating pressure for the hydraulic
machine is exceeded, it can result in material
damage and personal injury.
Always run the hydraulic machine with the correct
operating pressure, see "Technical data".
Only readjust the pressure relief valve (torque
control) on the machine according to procedure
and values described under maintenance. Note
that higher settings might lead to a higher torque,
which could harm the machine and result in
serious injury or death.
© 2015 Construction Tools EOOD | No. 3392 5189 01c | 2015-01-31
Original instructions
Safety and operating instructions

Water flushing

For diamond bit core drilling, water flushing is
required. Mount the water swivel and water hose on
the core drill as follows.
The water can be supplied directly from a source, or
a separate water kit can be used. A separate water
kit with pressure tank is available, see the spare parts
list.

Drill bit

Choosing drill bit

A correct drill bit is a condition for good operation.
To avoid unnecessary machine damage, it is
important to choose drill bits with a high quality.

Fitting and removing the drill bit

Smaller diameter drill bits are fitted directly into the
machine drive shaft (½" BSP). For larger diameter
drill bits, use an ½" BSP male x 1¼ UNC male drive
adaptor, which is included with the machine.
To prevent an accidental start:
Switch off the power supply and disconnect
1)
the machine from the power source.
Screw the drill bit into the machine.
2)
3)
Lock the spindle using a spanner and tighten
the drill bit.
Bleed the machine by pressing the start and
4)
stop device.
NOTICE Never cool a hot insertion tool in water, it
can result in brittleness and early failure.
13