Anolis ArcPower 144 Panduan Pengguna - Halaman 17
Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Peralatan Pencahayaan Anolis ArcPower 144. Anolis ArcPower 144 20 halaman.
zone Z blue;
zone Z white;
zone Z yellow;
zone Z cyan;
zone Z magenta;
zone Z blackout;
Z ...........means number of the zone (0-9)
red/green/blue/white/yellow/cyan/magenta....determines colour
blackout.......closes light output
;.............means end of character sequence
Examples: zone 3 green;
zone 0 blackout;
Type 2: Colour mixing-RGB
The syntax of the command is:
zone Z r,g,b;
Z............ means number of zone (0-9)
r .............means DMX value of the red colour(0-255)
g ............means DMX value of the green colour (0-255)
b ............means DMX value of the blue colour (0-255)
; .............means end of character sequence
, ..............values of colours have to be separated by a comma.
Examples: zone 0 234,126,165;
zone 1 5,18,28;
Type 3: Colour mixing-RGBW
The syntax of the command is:
zone Z r,g,b,w;
Z............ means number of zone (0-9)
r .............means DMX value of the red colour(0-255)
g ............means DMX value of the green colour (0-255)
b ............means DMX value of the blue colour (0-255)
w ............means DMX value of the white colour (0-255)
; .............means end of character sequence
, ..............values of colours have to be separated by a comma.
Examples: zone 0 156,145,171,211;
zone 1 5,18,28,148;
17