DSC MAXSYS PC4850 Panduan Instalasi - Halaman 8

Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Unit Kontrol DSC MAXSYS PC4850. DSC MAXSYS PC4850 16 halaman. Telephone entry module

DSC MAXSYS  PC4850 Panduan Instalasi

2.12 Connecting the PC4850 to Ground

Make a ground connection as shown below:

2.13 Connecting the Power

Once all other wiring is complete, power up the PC4850:
• After powering up the PC4850 for the first time, wait
for 10 seconds and then remove the shorting jumper J2.
During the normal operation of the PC4850, the
jumper must be kept removed.
• Connect the main board transformer to terminals AC1
and AC2, as shown.
• If connecting a backup battery, connect the red battery
lead to the +BAT terminal and the black lead to -BAT.
-BAT +BAT
12V
DC Backup
Supply
Use AWG #18
4

2.14 Lithium Batteries

There is a lithium battery on the module. Do not attempt
to replace this battery. There is a danger of explosion if
the battery is incorrectly replaced.
If the lithium battery stops working, return the circuit
board to the supplier. Batteries may cause a fire when in
contact with metal. If you need to dispose of the circuit
board and/or the lithium battery, wrap the battery in
non-conductive tape. Check with your local government
for battery disposal regulations.
WARNING: Do not store the batteries in such a way
that they come into contact with each other or with
any piece of metal. Explosion or fire may occur. Should
fire occur, use only dry chemical fire extinguishers. Do
not use water to put out the fire.
Do not heat the batteries. Do not dispose of the batter-
ies or circuit boards in a fire. Do not disassemble the
batteries. Do not apply pressure to or deform the bat-
teries. Ensure that the above precautions are strictly
observed by related departments, including, but not
limited to, production, sales and outside contractors.

2.15 Connecting Tamper

Please see diagram below for connecting tamper.
T1
Normally Closed
GND
Contact