Installing the ACX-3.2 (continued)
Level Matching
Many source units produce signal voltages in the area of 2 to 4 volts. However,
you typically only achieve these voltage levels when the volume is turned all
the way up. By following the level matching steps for the ACX-3.2 you will be
able to take full advantage of the high voltage output of your source.
1. Disconnect the RCA cables leading into your amplifiers, and make sure the
only RCA cables between your source unit and the ACX-3.2's main inputs
are attached. Turn the volume level knob on the ACX-3.2 to maximum.
2. Play a favorite audio track contains consistent, dynamic music and turn the
source unit's volume control up to its maximum level. (NOTE: Some source
units may produce distortion or "clipping" when their volume controls
are turned all of the way up. If this happens, you will hear distortion even
at low levels when you connect the rest of the system. If this is the case,
lower the source unit's volume level until you no longer hear distortion).
The volume control on the ACX-3.2 will now be the master volume control.
3. Using the included AudioControl guitar pick, or a small screwdriver,
adjust the Input Level control on the top of the ACX-3.2 until the yellow
Maximized LED starts to flicker with the music. (NOTE: If the Maximized
light does not come on because of the low output of the source unit, turn
the Input Level pot to maximum).
Important Tip: If the Maximized light does not come on, because of the
low output of the source unit, turn the Input Level to maximum. Please
refer to the amplifier manufacturer's specifications on input voltage
to determine whether you will need to decrease the Input Level on the ACX-3.2
to avoid clipping the next component in line. If the next component in line is an
AudioControl component, there is no need to re-adjust the Input Levels, because
they can handle the hot signal voltage the ACX-3.2 produces.
4. Turn off the entire system and attach the output RCAs from the ACX-3.2 to
the next component in line.
5. Turn down the gain control on your amplifiers to the least sensitive setting
which is turning the gain control counter clockwise. This will allow you to
drive a hotter signal in to your amplifiers.
13