Trouble Shooting
Ensure all tests are undertaken by a qualified, trained engineer and ensure safe
working practices are followed at all times.
Step 1: Basics
• Check power connection
• Ensure power is 12-32V DC / 24V AC 50-60Hz
• Check the photocell is working - cover photocell ,light should turn on
• Ensure power supply is suitably rated to product - check the specifications
Step 2: Lamp Test
• Check current draw of lamp corresponds to specification
• Check current of lamp - see instructions for correct current settings
To check lamp current remove +ve (red) lead from power supply and connect a
multimetre (set to 10A) in line with the lamp. (One lead of multimeter in common
(COM) other lead into 10A socket of multimeter; set multimeter to read Amps).
Step 3: Set up camera, lens and illumination
• Check alignment of lamp
• Check camera lens- fully open at night and set correctly
• Check model number to performance specification to ensure required distance
is achievable
Step 4: Call for further assistance
If the lamp is still not delivering the required performance, please contact Technical
Support for further assistance
Note down:
• Model number and serial number of illuminator
• Camera make and model
• Ideally, provide images that illustrate the problem
Safety Warning
• When the lamp is running, it is hot to touch. before touching switch off the
illuminator and allow to cool for a minimum of 10 minutes.
• The illuminator should be positioned so that prolonged staring into the
illuminator at a distance closed than 1m is not expected.
• The light source of this illuminator is not replaceable, when the light source
reaches its end of life the whole illuminator should be replaced.
• If the flexible power cord of the illuminator is damaged it should be exclusively
replaced by a qualified, trained engineer.
• This equipment is not suitable for us in locations where children are likely to be
present.