Appliance AWDH 124 Panduan Pengoperasian - Halaman 6
Jelajahi secara online atau unduh pdf Panduan Pengoperasian untuk Pendingin Udara Appliance AWDH 124. Appliance AWDH 124 18 halaman. 2.4kw capacity
Be fully aware of the weight of the air conditioner before attempting to lift it. Take all necessary
precautions to avoid damaging the product or causing personal injury. It is advisable to remove
the packaging only when the air conditioner has been located in the point of installation.
Carefully remove the adhesive strips positioned on the air conditioner. Packaging components
must be disposed correctly and not left within reach of children, since they are a potential source
of danger.
1.5 LIST OF ACCESSORIES(P0)
1. FASTENING BRACKET
2. REMOTE CONTROL
3. REMOTE CONTROL HOLDER
4. DRAINAGE PIPE
5. EXTERNAL GRATING
6. AIR INTAKE PIPE (160 mm.)
7. AIR DISCHARGE PIPE (150 mm.)
8. KIT OF SCREWS
9. GRATING FIXING CORD
10. INSTRUCTION MANUAL
11. PAPER TEMPLATE FOR WALL DRILLING (See page )
This product has been manufactured to comply with 2006/95/EC and with amendments 92/31/EEC
and 93/68/EEC
Waste electrical products should not be disposed of with household waste. Please recycle where
facilities exist. Check with your Local Authority or retailer for recycling advice.
Any batteries used in the remote control contain materials, which are hazardous to the environ-
ment. They must be removed from the remote control when they reach the end of their life and
disposed of responsibly.
1.6 TECHNICAL FEATURES(P1,P2)
Model AWDH 124
Cooling capacity * W (BTU/h)
Heating capacity * W (BTU/h)
Rated voltage (V)
Absorbed power in cooling** (kW)
Absorbed current in cooling** (A)
Absorbed power in heating** (kW)
Absorbed current in heating** (A)
Air flow (m
3
/h)
Noise level min-max (dB A)
Dehumidification capacity*** (L/24h)
Optional temperature (remote control)
Fuse
Refrigerant
Global warmer potential (GWP)
Dimensions H/W/D(mm)
Weight (Kg)
*
EN 14511-2004
**
To be used as indication
***
Moisture removal at 32°C, 80% RH
Environmental information: This equipment contains fluorinated greenhouse gases covered by the Kyoto Protocol. It
should only be serviced or dismantled by professional trained personnel.
This equipment contains R410A refrigerant in the amount as stated in the table above. Do not vent R410A into atmosp-
here: R410A, is a fluorinated greenhouse gas with a Global Warming Potential (GWP) = 1975
2400 (8200)
2350 (8000)
230
1.02
4.48
0.94
4.11
430
43-52
57
18-30°C
250V-T3.15L
R410A
1975
548x1008x234
45