Addvent AVIK20W Petunjuk Instalasi dan Panduan Pengguna - Halaman 2

Jelajahi secara online atau unduh pdf Petunjuk Instalasi dan Panduan Pengguna untuk Peralatan Rumput dan Taman Addvent AVIK20W. Addvent AVIK20W 2 halaman. Low energy insect killers

AVIKW[16]instructions
18/3/16
09:58
Safety Instructions
WARNINGS
Check the local voltage before working. As there is a danger of
G
electric shock DO NOT touch the internal high voltage grids.
NEVER put metal objects inside the mesh.
The appliance is for INDOOR USE only, but is NOT SUITABLE for
G
use in barns, stables or similar locations. The appliance is not to
be used where there may be flammable vapours or explosive
dust.
Install the appliance out of the reach of children.
G
To avoid electric shock, NEVER remove any fixed part of the
G
appliance.
DO NOT touch the high-voltage grid with any object when
powered.
If the supply cord, lamp, or any other part of appliance is
G
damaged, return the appliance to place of purchase for advice.
Repairs should be carried out by the manufacturer or qualified
electricians.
Page 2
WARNING
2
Installation
AVIK20W and AVIK40W
Before installation
These units are suitable for wall-mounting or may free-stand on a secure surface.
G Siting the unit: The unit should be sited at 90° to the major light source.
Ideally, the unit should be mounted as close to 2m from the floor as possible.
Avoid mounting in the airstream to prevent dead insect being blown away.
DO NOT mount above a food preparation area as the intention is to attract
the flying insect away from such areas. To avoid exposure to UV light, the unit
should be sited 1m away from any operator workstation.
G
Make certain that you have all the parts and appropriate tools for installation.
G
Ensure that the power is disconnected before installation.
Installation
Electrical
G
The electrical supply required for this unit is (single phase) 220V-240V AC,
50/60Hz.
NOTE: a circuit breaker (RCCB) may be required in certain installations.
Installation
G Fixing: The unit is supplied with suitable fixings
for mounting to a wall.
G
Drill and fix two screws to the wall.
G
Then using the fixing slots in the back cover – as
shown in figure 1 – slide the unit over the wall
fixing screws until it is located firmly.
Once installed, there should be easy access to
the power cord and plug to allow cleaning and
maintenance. The unit must be fixed in position
before connecting the electricity.
Operation
G The unit is switched on and off using the switch located top right hand side.
G For the operators safety, a micro switch will cut-off the power to the unit
when the collection tray is removed.
3
AVIKW
FIG 1