4. Plug the supplied flying lead connector into the keypad PC board
and splice the panel wiring to it, or wire directly to the terminal
block on the PC board (wire colors are marked next to terminals).
Wire colors and functions are described in the SPECIFICATIONS
section.
5. Re-attach the keypad to its case back.
6. Remove the clear protective films from the LCD display and keypad
labels.
ARMED
READY
LOCATION OF DEDICATED
PANIC KEYS. "D" KEY NOT USED
FOR PANIC FUNCTIONS.
SETTING THE KEYPAD ADDRESS
The keypad can be set for an address of 0-31 (the keypad will not
accept entries greater than 31), which is stored in EEROM memory.
The keypad's default address is 31 (non-addressable mode–some early
versions of 6139/6139R default to 11).
To change the keypad's address, do the following:
1. Enter address mode: Power up (plugin) the keypad. Within 60
seconds of power-up, press and hold down the [1] and [3] keys at the
same time for 3 seconds. (If unable to enter address mode, power up
and try again.)
The current keypad address will be displayed, and the cursor will be
under the "tens" digit. If 10 seconds have passed with no key entry,
the keypad automatically exits address mode.
down, power up and start address mode again.
REFER TO INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL FOR DETAILS ON LIMITATIONS OF THE ENTIRE ALARM SYSTEM.
Alarm Device Manufacturing Company, a Division of Pittway Corporation, and its divisions, subsidiaries and affiliates ("Seller"), 165 Eileen Way, Syosset, New York 11791, warrants its products
to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 24 months from the date stamp control on
the product or, for products not having an Ademco date stamp, for 12 months from date of original purchase unless the installation instructions or catalog sets forth a shorter period, in which
case the shorter period shall apply. Seller's obligation shall be limited to repairing or replacing, at its option, free of charge for materials or labor, any product which is proved not in compliance
with Seller's specifications or proves defective in materials or workmanship under normal use and service. Seller shall have no obligation under this Limited Warranty or otherwise if the product
is altered or improperly repaired or serviced by anyone other than Ademco factory service. For warranty service, return product transportation prepaid, to Ademco Factory Service, 165 Eileen
Way, Syosset, New York 11791.
THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE
DESCRIPTION ON THE FACE HEREOF. IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR
ANY OTHER WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S
OWN NEGLIGENCE OR FAULT.
Seller does not represent that the products it sells may not be compromised or circumvented; that the products will prevent any personal injury or property loss by burglary, robbery, fire or oth-
erwise; or that the products will in all cases provide adequate warning or protection. Customer understands that a properly installed and maintained alarm may only reduce the risk of a bur-
glary, robbery, fire or other events occurring without providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as
a result. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT
FAILED TO GIVE WARNING. HOWEVER, IF SELLER IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED
WARRANTY OR OTHERWISE, REGARDLESS OF CAUSE OR ORIGIN, SELLER'S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE
PRODUCT, WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER. This warranty replaces any previous warranties and is the only warranty made by Seller on
this product. No increase or alteration, written or verbal, of the obligations of this Limited Warranty is authorized.
¬19l
N6752V8 8/98
2
1
3
OFF
AWAY
STAY
4
5
6
MAX
TEST
BYPASS
7
8
9
INSTANT
CODE
CHIME
*
0
#
READY
PANIC
You must power
ADEMCO LIMITED WARRANTY
165 Eileen Way, Syosset, New York 11791
Copyright © 1993 PITTWAY CORPORATION
NOTE: The keypad will not enter address mode if the panel to which
it is connected is in programming mode.
2. Set the current address to "00": Press [0] to clear the current "tens"
digit. The cursor will move to the "ones" digit position. Press [0] to
clear the current "ones" digit. The cursor will move back to the
"tens" digit position.
3. Enter the keypad's address: Enter the proper "tens" digit of the
keypad's address. The cursor will move to the "ones" digit position.
Enter the proper "ones" digit of the keypad's address. Note that
address "31" sets the keypad to non-addressable mode.
4. Exit address mode:
Press [ ] to save the displayed address and exit address mode.
Remove
VIEWING THE KEYPAD ADDRESS
case back
by pushing
Press and hold down the [1] and [3] keys at the same time for about 3
down the
seconds. The current address is displayed. No key entry is allowed.
2 "snaps"
Press any key to exit or wait 10 seconds to exit viewing mode.
along the
keypad's
SPECIFICATIONS
top edge
Physical:
and pulling
the case
6128: 4-3/4"H x 5-3/4"W x 1"D (121mm x 146mm x 25.4mm)
apart.
6137/6137R: 4-3/4"H x 6-1/4"W x 1"D (121mm x 159mm x 26mm)
6138/6139/6139R: 4-3/4"H x 6-3/4"W x 1-1/4"D
Wiring:
Red:
(all Keypads) Black:
Blue:
Green:
Yellow:
Current:
6128:
40mA sounder on, 20mA standby, alarm sounder off.
6137/6137R: 85mA (ARMED LED lit, LCD backlight and sounder on),
reduces to 40mA when panel is operating in standby
mode (backlight off).
6139/6139R: 100mA (ARMED LED lit, LCD backlight and sounder
on), reduces to 40mA when panel is operating in standby
mode (backlight off).
Displays:
6138:
1 x 16 alpha-numeric supertwist LCD, backlit.
6139,6139R:
2 x 16 alpha-numeric supertwist LCD, backlit.
6128, 6137:
Fixed-Word LCD (6137 backlit).
Sounder:
Piezo-electric (fire alarm is loud, pulsing single tone;
(all Keypads) burglary alarm is loud, continuous, dual
tone).
(121mm x 159mm x 32mm)
+12VDC
Ground.
If present, not used.
Data to control panel.