"transmitting" indicator light shines when the door is opened, and the host touches off
the alarm, which means you have successfully install it. But when the light signal is
green, it means that the battery for the magnetic contact has electricity shortage and the
battery should be changed.
2. Install Passive Infrared Detector
Please put the battery of the infrared detectors at the proper position and mount it at the height
of 1.8-2 m with its lens aiming at the monitored area. And then turn on the power switch for test,
and the red indicator will shine. One minute later, the detector will be in the alert state. And at
the moment, if someone motioned in the monitored zone, the red indicator shines again and
sends the intrusive signal to the alarm panel to touch off the alarm.
3. Install the host
(1) Before starting installing the alarm host, make sure that the install location should be near
the telephone line and the power socket. When it being installed on the wall, please mark
the screw hole first on the wall for correct installation.
(2) Optional accessories: wired sensor, multi-beam sensor, wired panic emergency button,
external high siren ( Installation refers to Diagram 2)
Local Telecommunication
Line
Telephone
(3) Wired Sensor Wiring: there are two wired zones (Zone 2 and Zone 10), and they are
wireless and wired compatibility. When installing the wired sensors, please use the 4-core
wire. Take off the short-circuit wire at the ends of wired zone, and connect the positive
pole and negative pole of the detector to the "+12" and "-12" of the alarm panel
respectively (Note: please note the electrodes). And connect the signal terminals of the
sensor to the counterparts of the alarm panel without distinguishing the positive and
Panic Button Wired Sensor
Siren
BUS
input
Siren
Diagram2: Wiring Diagram
15
Short-circuit
Zone 2 Zone 10
Emergency