Jelajahi secara online atau unduh pdf Manual untuk Unit Kontrol Automationdirect.com Productivity 2000 P2-08DA-1. Automationdirect.com Productivity 2000 P2-08DA-1 8 halaman. Analog output
General Specifications
Operating Temperature
0º to 60ºC (32º to 140ºF)
Storage Temperature
-20º to 70ºC (-4º to 158ºF)
Humidity
5 to 95% (non-condensing)
Environmental Air
No corrosive gases permitted
Vibration
IEC60068-2-6 (Test Fc)
Shock
IEC60068-2-27 (Test Ea)
Field to Logic Side Isolation
1800VAC applied for 1 second
Insulation Resistance
> 10MΩ @ 500VDC
Heat Dissipation
700mW
Enclosure Type
Open Equipment
UL508 File E139594, Canada & USA
Agency Approvals
CE (EN61131-2*)
Module Keying to Backplane
Electronic
Module Location
Any I/O slot in a Productivity2000 System
Use ZIPLink Wiring System or removable terminal block
Field Wiring
(not included). See "Wiring Options" on page 5.
See the "EU Directive" topic in the Productivity2000
EU Directive
Help File. Information can also be obtained at:
www.productivity2000.com
Connector Type (not included) 18-position removable terminal block
Weight
90g (3.2 oz)
*Meets EMC and Safety requirements. See the D.O.C. for details.
2
www.productivity2000.com
Output Specifications
Output Channels (Commons)
8
Module Signal Output Range
4-20 mA
Output Signal Resolution
16-bit
Resolution Value of LSB
4-20 mA = 0.244 μA/count
(least significant bit)
1 LSB = 1 count
Data Range
0 to 65535 counts
Output Type (sourcing)
Current: 20mA max
Output Value in Fault Mode
Near 0mA
0 - 570Ω (19.2 VDC)
0 - 690Ω (21.6 VDC)
0 - 810Ω (24VDC)
Load Impedance
0 - 930Ω (26.4 VDC)
(Minimum External Power Supply)
0 - 1100Ω (30VDC)
Minimum Load 0 - 125Ω @ 0 - 45°C
Maximum Inductive Load
1mH
Allowed Load Type
Grounded
0.1% of range (Counts TBD)
Maximum Inaccuracy
(including temperature drift)
Maximum Full Scale Calibration
±0.025% of range maximum
Error (not including offset error)
Maximum Offset Calibration Error
±0.025% of range maximum
±25ppm/°C max full scale calibration change
Accuracy vs. Temperature
(±0.0025% of range/°C)
Max Crosstalk
-96dB, 1 LSB
±16 LSB maximum (±0.025% of full scale)
Linearity Error (End to End)
Monotonic with no missing codes
Output Stability and Repeatability
±10 count after 10 minute warm-up (typical)
Output Ripple
0.05% of full scale
Output Setting Time
300μs max, 5μs min (full scale change)
All Channel Update Rate
600μs
Maximum Continuous Overload
Outputs open circuit protected
Type of Output Protection
Electronically current limited to 20mA or less
Output Signal (power-up,-down)
4mA
External DC Power Required
24VDC @ 220mA (Loop Power Included)
Tech Support 770-844-4200