Input Type Setting
In the universal input card, place of jumper pin is different by input type.
Before setting the parameters, set the jumper pin channel 1 / 2 of universal input card (KRN-UI2)
depending on input specification as below figure.
Jumper pin
setting
CH 1 jumper
①
②
CH 2 jumper
③
Connections
Based on the back of KRN100-04000-00-0S
Dimensions
• Unit: mm, For the detailed drawings, follow the Autonics website.
146.7
□137
Mode Setting
→
key
→
key 3sec
→
key 3sec
RUN
→
key 3sec
→
key
→
key
→
key 3sec
Input
Input specification
disconnection
alarm
0 to 20 mA, 4 to 20 mA
4 to 20 mA
Terminal
side
TC, RTD, ± 60 mV, ± 200 mV
○
Terminal
side
± 2 V, 1 to 5 V, ± 5 V, -1 to 10 V ×
Terminal
side
SOURCE
100-240 VACᜠ
50/60 Hz, 55 VA
F.G.
Slot
Description
1 to 6
For universal input card
For digital input card, alarm output card,
7 to 10
transmitter power output card
C
For communication output card
18.6
177.5
■ Panel cut-out
≥ 175
□138
+0.1
0
■ Bracket
13.3
67.5
BRACKET
FIXING BOLT
Run / Stop recording
Parameter setting information output
Manual feed
(operating when recording in stopped)
Digital memo
Changing screen display
QUICK MENU
Parameter setting group
4-≤ R2
18, Bansong-ro 513Beon-gil, Haeundae-gu, Busan, Republic of Korea, 48002