Autonics ADIO-EI Panduan Produk - Halaman 9
Jelajahi secara online atau unduh pdf Panduan Produk untuk Sistem I/O Autonics ADIO-EI. Autonics ADIO-EI 10 halaman. Remote i/o boxes (ethernet/ip)
Indicators
■ Status indicator
01. The power supply of sensor
Indicator
LED color
Status
ON
Green
Flashing
US
(1 Hz)
Flashing
Red
(1 Hz)
02. The power supply of actuator
Indicator
LED color
Status
Green
ON
Flashing
UA
(1 Hz)
Red
ON
03. Error status
Indicator
LED color
Status
Flashing
Green
(1 Hz)
US, UA
Red
ON
04. Module status
Indicator
LED color
Status
OFF
Green / Red
Flashing
ON
Green
MOD
Flashing
ON
Red
Flashing
05. Network status
Indicator
LED color
Status
OFF
Green / Red
Flashing
ON
Green
NET
Flashing
ON
Red
Flashing
06. Ethernet connection
Indicator
LED color
Status
OFF
Green
L/A1
ON
L/A2
Yellow
Flashing
07. Transmission rate of the Ethernet
Indicator
LED color
Status
OFF
100
Green
ON
Description
Applied voltage: normal
The settings of the rotary switches is
changing.
Applied voltage: low (< 18 VDCᜡ)
Description
Applied voltage: normal
Applied voltage: low (< 18 VDCᜡ),
Error in the rotary switches
Applied voltage: none (< 10 VDCᜡ)
Description
Error in the rotary switches
(the applied voltage: normal)
ADIO initialization failure
Description
No error
Device self-testing: Power
Operating
Standby: Device is not configured.
(no IP address)
Unrecoverable error (module failed)
Error in device configuration
(invalid configuration)
Description
No Power and IP address
Device self-testing: Power
The connection is established.
No connection
IP address conflict:
Another device has the same IP address.
Connection timeout
Description
No Ethernet connection
The Ethernet connection is established.
Data transmission
Description
Transmission rate: 10 Mbps
Transmission rate: 100 Mbps
■ I/O port indicator
01. Pin 4 (C/Q)
Indicator
LED color
Status
OFF
Yellow
ON
ON
Green
Flashing
(1 Hz)
0
Flashing
(2 Hz)
Red
ON
02. Pin 2 (I/Q)
Indicator
LED color
Status
OFF
1
Yellow
ON
03. The power supply of the I/O port
Indicator
LED color
Status
Flashing
0,1
Red
(1 Hz)
Description
DI/DO: pin 4 OFF
DI/DO: pin 4 ON
Port configuration: IO-Link
Port configuration: IO-Link,
No IO-Link device found
IO-Link configuration error
• Validation failed, Invalid data length,
Data Storage error
• NPN: Short circuit occurred on the output of
pin 4 and pin 1
• PNP: Short circuit occurred on the output of
pin 4 and pin 3
Description
DI: pin 2 OFF
DI: pin 2 ON
Description
Short circuit occurred
in the I/O supply power (pin 1, 3)