HighPoint SSD7505 Panduan Instalasi - Halaman 13

Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Perangkat Keras Komputer HighPoint SSD7505. HighPoint SSD7505 14 halaman. Using nvme raid aics with the dell precision 3930 rack workstation
Juga untuk HighPoint SSD7505: Panduan Instalasi (12 halaman), Panduan Instalasi (15 halaman), Panduan Instalasi Cepat (6 halaman), Panduan Instalasi Cepat (8 halaman), Panduan Instalasi (14 halaman), Panduan Instalasi (16 halaman), Panduan Instalasi (19 halaman), Menggunakan Manual (19 halaman)

HighPoint SSD7505 Panduan Instalasi
SSD7505 Linux CentOS8.2 Installation Guide
c. The driver installation is complete. Reboot to enter the system where the new kernel
is located.
Appendix A
Support command:
help/info/quit/exit/create/delete.
Ÿ Create Command
Syntax
Create Array Type (RAID0/RAID1/RAID10) Member Disk list
(1/1,1/2|*)Capacity(100|*)
Examples
<<< create RAID0
<<< create RAID0 *
<<< create RAID0 * *
Create RAID0 array with all disks and with maximum capacity.
<<< create RAID1 1/1, 1/3 10
Create RAID1 array with disk 1/1 and 1/3 and with 10GB
capacity.
<<< create RAID10
<<< create RAID10 *
<<< create RAID10 * *
Create RAID10 array with all disks and with maximum
capacity.
Ÿ Delete Command
Syntax
delete {array ID}
Examples
<<< delete 1
Delete the first array from Logical device list.
<<< delete 2
Delete the second array from Logical device list.
- 11 -