The appliance is supplied with a connection
cable. This has to be provided with a proper
plug, able to support the load marked on the
identification plate. To connect the plug to the
cable, follow the recommendation given in fol-
lowing figure.
3
Replacement of the connection cable
The replacement of the connection cable re-
quires the specific equipment of a technician.
In this case, only cable type H05V2V2-F T90
must be used. The cable section must be suit-
able to the voltage and the working temper-
ature. The yellow/green earth wire
approximately the same length as the brown
(or black) phase wire
Clamping connections must be correctly instal-
led by a qualified electrician (previous figure).

Environment concerns

The symbol
on the product or on its
packaging indicates that this product may not
be treated as household waste. Instead it
should be taken to the appropriate collection
point for the recycling of electrical and
electronic equipment. By ensuring this product
is disposed of correctly, you will help prevent
potential negative consequences for the
environment and human health, which could
otherwise be caused by inappropriate waste
handling of this product. For more detailed
information about recycling of this product,
please contact your local council, your
1
2
2
must be
1
and neutral wire
The plug has to be fitted in a proper socket. If
connecting the appliance directly to the elec-
tric system, it is necessary that you install a
double pole switch between the appliance
and the electricity supply, with a minimum gap
of 3 mm. between the switch contacts and of a
type suitable for the required load in compli-
ance with the current rules.
The connection cable has to be placed in order
that, in each part, it cannot reach a tempera-
ture 90 °C higher than the room temperature.
The brown (or black) phase cable (fitted in the
terminal block contact marked with "L") must
always be connected to the network phase.
Warning! Once connected to the mains
supply check that all cooking zones are
ready for use by briefly setting each to
maximum power.
3
.
household waste disposal service or the shop
where you purchased the product.
Packaging materials
The materials with the symbol
ble. Dispose the packaging in a suitable col-
lection containers to recycle it.
Before disposal of appliance
Warning! Do these steps to dispose the
appliance:
• Pull the mains plug out of the mains socket.
• Cut off the mains cable and discard it.
9