Technical table
Category
Gas
Max.
Supply
press.
press.**
(-)
(-)
(mbar)
AP-1 series
I2L, I2ELL
G25
50
I2H, I2E, I2ELL G20
50
I3P
G31
200
I3P
G31
310
I3P
G31
1400
Biogas
x
75
AP-2 series
I2L, I2ELL
G25
50
I2H, I2E, I2ELL G20
50
I2H, I2E
G20
300
I3B/P
G30
300
I3P
G31
200
I3P
G31
300
I3P
G31
1000
I3P
G31
1400
I3P
G31
1400
I3P
G31
2000
AP-3 series
I2L, I2ELL
G25
50
I2H, I2E, I2ELL G20
50
I3P
G31
200
I3P
G31
310
I3P
G31
1400
I3P
G31
1400
Biogas
-
75
** In case the heater is equipped with a thermostat (T, Ti) with bypass injector the heater shall be operated on maximum supply pressure only. See also the
pressure information on the data plate. Note that the minimum heat input with a thermostat is sometimes a bit higher than without thermostat.
Conversion calculation from gross heat input kW(Hs) to nett heat input kW(Hi):
Propane: divide gross heat input kW(Hs) by factor 1,09 (example: 1,20 kW(Hs) / 1,09 = 1,10 kW(Hi)
Natural gas: divide gross heat input kW(Hs) by factor 1,11 (example: 1,20 kW(Hs) / 1,11 = 1,08 kW(Hi)
G31 = propane; G20 = natural gas (100% methane); G25 = natural gas (86% methane); Biogas = 60% methane + 40% carbon dioxide
Version: April 2018
Min.
Max.
Min.
Supply
Heat
Heat
consumption
Input
Input
(mbar) (kW Hs)
(kW Hs)
(g/h or m3/h)
25
1,3
0,9
0,15 m3/h
25
0,95
0,67
0,09 m3/h
5
1,25
0,19
25
1,15
0,3
30
1,1
0,16
(T=0,5)
10
1,0
0,33
0,18 m3/h
25
3,5
2,45
0,39 m3/h
25
3,5
2,45
0,35 m3/h
10
5,1
0,9
0,48 m3/h
5
5,3
0,6
385 g/h
5
4,8
0,75
345 g/h
30
5,0
1,6
360 g/h
20
5,7
0,8
410 gr/h
20
5,6
0,65
400 g/h
(T=1,2)
20
4,6
0,55
329 g/h
20
5,4
0,5
386 g/h
(T=1,4)
25
1,6
0,96
0,18 m3/h
25
1,6
0,96
0,15 m3/h
100
2,0
1,55
144 g/h
25
1,7
0,48
121 g/h
20
1,95
0,21
140 g/h
(T=0,75)
20
1,2
0,15
10
1,5
0,5
0,26 m3/h
12
Gas
Main
By-pass
Venturi
Injector
injector
(1x)
T **(1x)
(mm)
(mm)
(mm)
0,71
x
11
0,55
x
9
89 g/h
0,36
x
7,5
82 g/h
0,32
x
7,5
79 g/h
0,22
0,16
6,5
0,75
x
6,5
1,15
1,3
13
1,05
1,2
13
0,82
0,34
10,5
0,61
0,22
14
0,71
x
14
0,66
0,39
14
0,52
x
11
0,47
0,22
10
0,45
x
11
0,41
0,22
10
0,82
x
11
0,74
x
11
0,47
x
14
0,39
0,22
11,5
0,27
0,18
7,5
87 g/h
0,23
-
6,5
0,91
-
7,5
manual number: 0009 0420EN
Ring
NOx
Remarks
Injector
class
Holder
(-)
(-)
(-)
7
x
x
5
x
x
5
x
x
5
x
x
5
1
0063CS3936
5
x
x
7
1
0063CS3936
7
1
0063CS3936
5
1
0063CS3936
5
x
x
4
x
x
8
1
0063CS3936
6
x
x
5
1
0063CS3936
4
x
(Ha>1400m)
4
x
x
9
x
x
9
x
x
6
x
x
8
x
(ball gauze burner)
5
1
0063CS3936
6
-
(Ha>1400m)
6
-
-