AEG 35944G Panduan Pengoperasian dan Instalasi - Halaman 22
Jelajahi secara online atau unduh pdf Panduan Pengoperasian dan Instalasi untuk Kompor AEG 35944G. AEG 35944G 26 halaman. Gas hobs
Juga untuk AEG 35944G: Petunjuk Pengoperasian dan Pemasangan (26 halaman), Petunjuk Pengoperasian dan Pemasangan (26 halaman), Petunjuk Pengoperasian dan Pemasangan (26 halaman), Petunjuk Pengoperasian dan Pemasangan (27 halaman)
Fault Finding
Preliminary Electrical Systems Check
START
Isolate appliance
and carry out:
A: Earth Continuity
check.
NO
Has inlet fuse blown?
NO
Inlet wiring
faulty.
Rectify any
fault.
Isolate appliance and
carry out:
B: Insulation check.
Rectify any fault
including replacing
fuses as necessary.
22
Y E S
C a r r y o u t :
C : P o l a r i t y c h e c k .
Y E S
PLUG (with cover removed)
Earth Wire
Green/Yellow
Neutral Wire
Blue
Brown
Blue
Brown
Carry out:
D: Resistance to
Earth check.
Electricity supply
should now be
satisfactory.
(face view)
( )
N
Blue
Green
Yellow
Green
Yellow
SOCKET
( )
E
L