Fujitsu ScanSnap iScanner fi-6010N Panduan Memulai - Halaman 9

Jelajahi secara online atau unduh pdf Panduan Memulai untuk Pemindai Fujitsu ScanSnap iScanner fi-6010N. Fujitsu ScanSnap iScanner fi-6010N 21 halaman. Network adf scanner
Juga untuk Fujitsu ScanSnap iScanner fi-6010N: Spesifikasi (2 halaman), Panduan Memulai (21 halaman), Brosur & Spesifikasi (2 halaman), Panduan Memulai (45 halaman), Petunjuk Pembersihan (2 halaman), Petunjuk Pembersihan (2 halaman)

Fujitsu ScanSnap iScanner fi-6010N Panduan Memulai
4. Press the [OK] button.
D The restart confirmation screen appears.
5. Press the [Later] button.
D The current scanner name, or changed scanner
name after next restart, is displayed.
If the scanner name is the same as
one already in use, network communi-
HINT
cation problems will occur. In this
case, try the following steps:
1. Disconnect the LAN cable, press
the [Shutdown] button on the
touch panel, and turn the scan-
ner off.
2. Reboot the scanner with the
LAN cable disconnected, and
enter a non-duplicate scanner
name.
3. Reboot the scanner again.
4. Re-connect the LAN cable to the
scanner.
Restart may be performed after all necessary settings
have been completed.
Continue with the Region/Timezone settings.

3.4 Setting the Region/Timezone

1. Select the [System Settings] tab on the top menu.
2. Select the [Region/Timezone] tab on the left
side menu.
D The "Region/Timezone" screen appears.
3. Press the [List] button for the "Timezone" input
field.
The default timezone is "(GMT+09:00) Osaka,
Sapporo, Tokyo".
D A list of timezones appears.
4. Select a timezone.
5. Select whether "Daylight Savings Time" should
be on or off.
This option is not shown for timezones where
daylight savings time is not used.
6. Press the [OK] button.
D The Region/Timezone is set.
Continue with IP address/DHCP settings.

3.5 Setting the IP Address/DHCP

An IP address must be set in order to connect the scan-
ner to a network.
Do not use an IP address that
ATTENTION
already exists in the network.
IP address duplication will cause
an error during setup.
1. Select the [Network Settings] tab on the top
menu.
2. Select the [IP Address] tab on the left side
menu.
D The IP address/DHCP screen appears.
7
3. Set the scanner's IP address. This may be
done automatically, by pressing the DHCP [On]
button.
The IP address may also be set manually, by
pressing the DHCP [Off] button and entering
the following numerical addresses:
z IP Address
z Subnet Mask
z Default Gateway
4. Press the [OK] button.
D The information entered is set.
If the IP address is the same as one
HINT
already in use, network communica-
tion problems will occur. In this case,
try the following steps:
1. Disconnect the LAN cable, press
the [Shutdown] button on the
touch panel, and turn the scan-
ner off.
2. Reboot the scanner with the
LAN cable still disconnected,
and enter a non-duplicate IP
address.
3. Re-connect the LAN cable to the
scanner.
When DHCP is set to "On", the follow-
ing settings are assigned by the
DHCP:
z IP Address
z Subnet Mask
z Default Gateway
z DNS Server
z WINS Server
z Domain Suffix
Even if DNS or WINS server is set, pri-
ority is given to the scanner settings
over the DHCP settings.
Continue with the connection settings.

3.6 Setting the Admin Network

Set the network settings for connecting to a scanner
from the Admin Tool or Central Admin Server.
1. Select the [Network Settings] tab on the top
menu.
2. Select the [Admin Network] tab on the left side
menu.
D The "Admin Network" screen appears.
3. Enter a port number from 1 to 65535, to be
used by the scanner to communicate with the
Admin Tool or Central Admin Server.
The default setting is 80.
z Port numbers 135, 139, 445, and
ATTENTION
numbers from 1025 to 1124, cannot
be specified as they are already
reserved in the scanner.
z If port numbers other than
HTTP:80, HTTPS:443 are to be
specified, it is recommended that
numbers over 5000 are used. If a
port number lower than 5000 is
specified, verify the Admin Tool
connectivity with the port number
first.
8