Fujitsu ETERNUS DX8700 S2 Panduan Konfigurasi - Halaman 23
Jelajahi secara online atau unduh pdf Panduan Konfigurasi untuk Penyimpanan Fujitsu ETERNUS DX8700 S2. Fujitsu ETERNUS DX8700 S2 28 halaman. Disk storage system settings
Juga untuk Fujitsu ETERNUS DX8700 S2: Panduan Pengguna (35 halaman), Panduan Pengguna (42 halaman), Panduan Konfigurasi (15 halaman)
Chapter 7
Checking Connections
7.2
Setting Up the Server to Recognize the Logical Units
Check that all connected devices are listed in the ioscan output and "CLAIMED" is displayed in "S/W
State".
The following example shows the output of ioscan (LegacyView) when ETERNUS DX storage systems are
connected to a server.
# ioscan
H/W Path
============================================================
:
255/0
255/0/0.0
255/0/0.0.0
255/0/0.0.0.0
255/0/0.0.0.1
255/0/0.0.0.2
255/0/0.0.0.3
255/0/0.0.0.4
:
#
When the ETERNUS DX storage systems are connected for the first time, the device file (for exam-
ple, /dev/dsk/c4t0d0) sometimes may not be created.
If this happens, use the "insf" command to create the device file. Specify the hardware path name as
follows, and execute.
# insf -H hw_path_to_device -e
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (iSCSI) for HP-UX
Class
iscsi
ext_bus
target
disk
disk
disk
disk
disk
23
Copyright 2014 FUJITSU LIMITED
Description
iSCSI Virtual Node
iSCSI-SCSI Protocol Interface
FUJITSU ETERNUS_DXL
FUJITSU ETERNUS_DXL
FUJITSU ETERNUS_DXL
FUJITSU ETERNUS_DXL
FUJITSU ETERNUS_DXL
P3AM-3402-14ENZ0