Hobs installation
Suitable precautions must be taken to ensure that the
installation is in compliance with current accident-prevention
regulations regarding electrical and gas connections. For
trouble-free operation of the appliance set into kitchen units,
the minimum distances indicated in fig.3 should be complied
with and the adjoining surfaces and rear wall should be
capable of withstanding a surface temperature of 65 °C.
Installation of PP 63/93 G hobs combined with 60/90
cm oven.
Size of cut-out for hob installation
Dimensions for
Model
building-in
PP 63 G
695x490
PP 93 G
948x490
fig.3
"Y"
"X"
Minimum Dimensions
Maximum Dimensions
695
155
948
155
fig.5
fig.4
Installation above a built-in oven
Both the electricity supply cable and the gas pipe must not
touch hot parts of the oven housing, in order to avoid
overheating.
Suitable air vents should be provided for as shown in fig.4
(inlet at least 200 cm² from the bottom, outlet at least 60
cm² from the top part for 60 cm ovens, and at least 90 cm2
for 90 cm ovens) to allow adequate ventilation inside the
housing unit.
When installing above a built-under oven without forced
cooling ventilation, a wooden panel "A" (fig.4) should be
installed beneath the hob as insulation, positioning it at a
minimum distance of 15 mm from the hob housing.
This wooden panel must be removable in order to allow for
any maintenance operations beneath the hob.
If the hob is installed on a base unit with doors, hob operation
is not influenced by the opening and closing of these doors.
Cooking
Area
Removable
wall panel for
maintenance
work
Base Side Panels for 60 and 90 cm oven
Fixing to the unit
Fix the provided sealing gasket "G" under the outer edge of
the hob;
To fix hobs from the PP 63/93 G series to the unit, four
brackets have been provided to fit on as indicated in fig.5 ;
12
Controls
Area
MIN. 40 mm.
*
For TOPS which are
B
less than 40 mm thick,
a hollow must be made
on the top part of side
panel "B".
*