Aqua Mundus GreaseShield 1000-PF Panduan Instalasi

Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Sistem Penyaringan Air Aqua Mundus GreaseShield 1000-PF. Aqua Mundus GreaseShield 1000-PF 2 halaman.

Installation Guide - GreaseShield
GS1000 Unit: Ensure that there is sufficient clearance above and to the right of the unit for
servicing purposes (5.9"/150mm minimum).
Inlet Pipe - 1½"/40mm: To be piped with a sufficient fall of no less than 1 in 40.
Outlet Pipe - 2"/50mm: To be piped with a sufficient fall of no less than 1 in 40.
Pre-Filter: Ensure sufficient height above the Pre-Filter to allow for removal and daily maintenance of Pre-Filter basket.
Pre-Filter Basket: A Pre-Filter basket must be installed into the pre-filter at all times.
Pre-Filter Support Bar: The support bar must be installed when attaching the Pre-Filter
Pre-Filter Adaptor Bracket: To be fixed onto the top of the GS1000 unit so that the Pre-Filter can be mounted.
Vortex Flow Controller: Must be fitted to the Pre-Filter inlet connection.
Sampling Point: Connected to the outlet of the unit: it is essential in the analysis of effluent leaving the unit.
Running Trap: The outlet of unit must be fitted with a running trap to reduce foul smells.
FOG Container: Ensure that the container is not restricted or blocked for daily maintenance.
Hot Water Solenoid Valve: Hot water must be connected to the unit using the¾" BSP (F/F) Red PVC Hose provided, water
supply must not exceed 3 bar pressure and 60
used. Mains water connections must be made via a WRAS approved isolation valve which follows a WRAS approved double
check valve.
Power Lead: The unit must be plugged into a 13 amp rated IP56 socket located below counter level.
Interconnecting Pipework: All pipework must be clipped and properly supported.
Stainless Steel Hygiene Stand {Optional Extra): GS1000 unit should be installed on a Stainless Steel Hygiene stand. It can
be adjusted up to 2"/50mm in height to allow the unit to be levelled on uneven surfaces and provide access for cleaning.
Award Winning Technology
lOOO-PF
®
C/140
F. In the case of high pressure a pressure reducing valve must be
°
°
vs 04/02/2020
Web: www.aquamundus.com Phone
number 01386832205 Email: