Dell 3250 Panduan Produk - Halaman 25

Jelajahi secara online atau unduh pdf Panduan Produk untuk Laptop Dell 3250. Dell 3250 37 halaman. Product guide (.pdf)
Juga untuk Dell 3250: Pembaruan Informasi (32 halaman), Panduan Pemilik (39 halaman), Panduan Pemilik (39 halaman), Panduan Memulai Cepat (2 halaman)

Dell 3250 Panduan Produk
Intel® Server Platform SR870BH2
8.2

Processor

8.2.1

Processor Debug Methodology

1) Enter Setup, startup options, select processor retest – Save and Exit (F10) reset system.
2) Run Platform Diagnostic test (located on Resource CD); if error persists perform the
following checks and steps:
Turn off and remove AC source power; remove top cover and processor air duct.
Reseat DC harness to power pod. Check to see that processor is locked (locking flag
or tab on the side of processor socket is visible).
Check to see that the four processor screws are tightened to 6-inch pounds (Use T-
15 Torx – do not over tighten). If tab is not visible, loosen the four captive mounting
screws and lock the processor (if tab is visible = locked, use 2.5mm Allen clockwise
¼ turn to lock) tighten the four mounting screws replace covers, reconnect AC
source, re-boot / re- run test.
If failure symptom persists:
1. Turn off and remove AC source power; remove top cover and processor air duct.
2. Remove DC power harness from power pod, remove power pod (loosen 4 captive
screws / slide pod away from processor to disengage).
3. Remove and inspect pins on processor (loosen 4 captive screws on processor, turn lock
tab counterclockwise ¼ turn, "tab not visible", lift processor to disengage).
4. Reseat processor and power pod (repeat above steps in reverse order) and re-run tests.
5. Replace / swap power pods or BSP (1st) with APP (2nd) processor.
6. Replace covers, reconnect AC source, restart system.
7. Re-run test in single processor mode (socket 1 must be populated to boot, Socket 2 will
auto terminate).
8.2.2

Processor Component Isolation

If after reseating or swapping component positions, the suspect component cannot be located
(i.e. DC harness, Power pod or Processor) and the failure persists - Replace the main board.
Revision 1.1
Debug Methodology and Failure Isolation
19