ABB 2TLA020009R0600 Manual Petunjuk Asli - Halaman 13

Jelajahi secara online atau unduh pdf Manual Petunjuk Asli untuk Peralatan Industri ABB 2TLA020009R0600. ABB 2TLA020009R0600 20 halaman. Safety light beam

ABB 2TLA020009R0600 Manual Petunjuk Asli
Calculation of minimum distance (worst case):
x = L × tan (2 )
where
x = minimum distance between two pairs
L = distance between transmitter and receiver
= maximum spreading angle of light disturbance
NB: Example values are given in
Reflecting surfaces
The Spot units must be set up in such a way that a reflecting surface may never be allowed to redirect the light
from the transmitter into the receiver. The minimum distance to a reflective surface (horizontal or vertical) from
which the Spot pair may be mounted is calculated depending on the distance between the transmitter and receiver.
Reflective surface
Spot T
= 2.5
Calculation of minimum distance:
If the distance (L) between the transmitter and receiver is less than or equal to 3 meters (L
distance (x) is 131 mm.
If the distance (L) between transmitter and receiver is greater than 3 meters (L > 3 m) then the following formula
applies:
x = L × tan ( )
where
x = minimum distance between Spot and reflective surface
L = distance between transmitter and receiver
= maximum spreading angle of light disturbance
NB: Example values are given in
2TLC172178M0201, rev. D
2011-11-15
.
Table 2
L
.
Table 3
x
Spot R
13
Table 3
L
x
3 m
131 mm
5 m
0.22 m
10 m
0.44 m
20 m
0.87 m
35 m
1.53 m
3 m) the minimum
www.abb.com/lowvoltage