Dell PowerEdge M710 Panduan Memulai - Halaman 9

Jelajahi secara online atau unduh pdf Panduan Memulai untuk Beralih Dell PowerEdge M710. Dell PowerEdge M710 12 halaman. Dell poweredge blade servers getting started guide
Juga untuk Dell PowerEdge M710: Pembaruan Informasi (38 halaman), Manual Pembaruan (44 halaman), Manual Pembaruan (21 halaman), Manual Pembaruan (14 halaman), Panduan Instalasi (7 halaman), Manual Pembaruan (1 halaman), Panduan Memulai (12 halaman), Buku Panduan Teknis (31 halaman), Panduan Portofolio (27 halaman), Panduan Memulai (14 halaman), Panduan Memulai (12 halaman)

Dell PowerEdge M710 Panduan Memulai
Power — Blades
Coin-cell battery
Power — Enclosure
AC/DC power supply (per power supply
module)
Wattage
Connector
Heat dissipation
Maximum inrush current
System Voltage Requirements
NOTE: This system is also designed to be
connected to IT power systems with a
phase to phase voltage not exceeding
230 V.
NOTE: Heat dissipation is calculated by
using the power supply wattage rating.
Physical — Blades
PowerEdge M915
Height
Width
Depth
Weight (maximum)
PowerEdge M910
Height
Width
Depth
Weight (maximum)
PowerEdge M710 and M610x
3 V CR2032 Lithium coin cell
2360 W and 2700 W
IEC C20
1205 BTU/hr (maximum)
Under typical line conditions and over
the entire system ambient operating
range, the inrush current may reach 55 A
per power supply for 10 ms or less.
43 A, 200 V AC to 240 V AC, 50 Hz/60 Hz
(2360 W power supply)
16 A, 100 V AC to 240 V AC, 50 Hz/60 Hz
(2700 W power supply)
38.5 cm (15.2 inch)
5 cm (2 inch)
48.6 cm (19.2 inch)
12.7 kg (28 lb)
38.5 cm (15.2 inch)
5 cm (2 inch)
48.6 cm (19.2 inch)
13.1 kg (29 lb)
9