Juga untuk Dell PowerEdge M910: Manual Pembaruan (44 halaman), Manual Pembaruan (21 halaman), Manual Pembaruan (14 halaman), Panduan Instalasi (7 halaman), Manual Pembaruan (28 halaman), Panduan Memulai (12 halaman), Panduan Memulai (12 halaman), Panduan Teknis (46 halaman), Panduan Portofolio (27 halaman), Panduan Memulai (14 halaman), Panduan Memulai (12 halaman), Panduan Teknis (49 halaman)

Dell PowerEdge M910 Panduan Teknis

Acoustics

Adherence to Dell's high sound quality standards. Sound quality is different from sound power level
and sound pressure level in that it describes how humans respond to annoyances in sound, such as
whistles, hums, etc. One of the sound quality metrics in the Dell specification is prominence ratio of
a tone, as listed in the table below.
Acoustical performance of typical configuration: When installed in the M1000e blade chassis,
typical configuration (shown in Table 4) of M910 blade results in the following idle acoustical
performance in 23±2°C ambient:
Table 4.

Definitions:

Standby: AC power is connected to power supply units but system is not turned on.
Idle: Reference ISO 7779 (1999) definition 3.1.7; system is running in its OS but no other specific
activity.
Stressed processor: An operating mode per ISO 7779 (1999) definition 3.1.6. The software
SPECPower_ssj2008 is utilized to stress the processors. SPECPower is set to 50 percent loading.
LwA–UL: The upper limit sound power level (LwA) calculated per section 4.4.2 of ISO 9296
(1988) and measured in accordance to ISO 7779 (1999).
LpA: Average bystander A-Weighted sound pressure level. The system is placed in a rack with its
bottom at 25 cm from the floor. The acoustic transducers are at the four bystander positions, ref
ISO 7779 (1999) Section 8.6.2.
Prominent tone: Criteria of D.5 and D.8 of ECMA-74 9th ed. (2005) are followed to determine if
discrete tones are prominent. The system is placed in a rack with its bottom at 75 cm from the
floor. The acoustic transducer is at front bystander position, ref ISO 7779 (1999) Section 8.6.2.
PowerEdge M910 Technical Guide
LwA–UL = 8.1 bels and no prominent tones
Typical configuration used in acoustical testing
Chassis
Description
Blade
M910
Slots populated
1, 2, 3, 4
Power supply
2300-W
Blanks
Blank modules
System Fans
M1000e fan
Blade internals
Description
Intel Xeon processor 7500
CPU
series 105W
DIMM
4GB DDR3
Mezz Cards
Dual-port Broadcom 5709
HDD
SAS 2.5" 146GB, 10krpm
17
Quantity
4
6
8
9
Quantity
2
24
4
2