Miele PW 6163 EL/D Rencana Instalasi - Halaman 10
Jelajahi secara online atau unduh pdf Rencana Instalasi untuk Mesin cuci Miele PW 6163 EL/D. Miele PW 6163 EL/D 16 halaman.
Machine connections:
Electrical
1. Standard voltage (as supplied)
connection
Deviations herefrom:
2. Standard voltage (as supplied)
Alternative voltage
Connection using multi-pole wall socket in compliance
with IEC 60309 and IEC 60947 is recommended in
order to simplify electrical tests.
Install mains isolator according to IEC 60947 on hard-
wired connection. Wall socket or mains isolator must
be accessible after installation.
The use of an earth leakage circuit breaker (ELCB) is
strongly recommended. A type B RCD (residual
current device) must then be used.
If necessary, equipotential bonding with good
galvanic contact must be provided in accordance with
all appropriate national and local regulations.
Steam
Steam pressure
connection
Boiling point
(Steam direct)
Heater rating
Volume flow
Connection thread (on site)
Steam valve, steam filter, steam stopcock and non-
return valve must be provided on site.
Note installation instructions for steam-heated Miele
washer-extractors.
Cold water
Min. flow pressure
(Soft water)
Max. pressure
Volume flow necessary
Max. volume stream in absence of hot and raw water
supplies.
Special version, unit without detergent dispenser.
On-site connection thread according to DIN 44 991
Length of supply hose
(supplied: 2 connection hoses + Y piece)
Water requirements with standard connection to hot
water in 60°C programme ( average value)
In the absence of a hot water supply, connect to
alternative supply.
In the absence of a raw water supply, connect to
alternative supply.
Installationsplan / Installation plan: PW 6163 EL/D
Datum / Date: 16.03.2011
Frequency
Rated load
Fuse rating
Connection cable (to be ordered
separately)
Minimum cross-sectional area
with threaded cable connector
Frequency
Rated load
Fuse rating
Connection cable (to be ordered
separately)
Minimum cross-sectional area
with threaded cable connector
Frequency
Rated load
Fuse rating
Connection cable (to be ordered
separately)
Minimum cross-sectional area
with threaded cable connector
Volume flow necessary
Max. throughput (if hot and raw water supply is
not available)
V
3N AC 380-415
Hz
50 - 60
kW
18.0
A
3 × 25
mm²
5 × 4
M 32 x 1.5
V
3 AC 220-240
Hz
50 - 60
kW
18.0
A
3 × 50
mm²
4 × 10
M 40 x 1.5
V
3 AC 208
Hz
60
kW
15.3
A
3 × 50
mm²
4 × 10
M 40 x 1.5
kPa
≤ 400
°C
≤ 152
kW
29
kg/h
46
Inch
½" internal thread
kPa
100
kPa
1000
l/min
26
l/min
79.5
l/min
20
l/min
77.5
Inch
1" external thread
mm
1500
l/h
not yet available
Seite / Page: 10