de.a. Dead man
During dead man functioning mode the gate moves only with a permanent command.
The enabled commands are OPEN and CLOSE. SS and PED are disabled. During dead man functioning all the automatic movements are disabled,
like short or total inversions. All safety devices are disabled except for STOP.
se.r. Setting threshold of cycles for assistance request
It is possible to set a number of cycles before the request of assistance. Once the limit is reached the next cycles will be done with fast blinking (only if
FPr enabled)
se.f. Continuous flashing light for assistance request
Once limit se.r. is reached the flashing light will blink also with the gate closed to show the request of assistance.
tr.S. Viewing of the memory position for a single transmitter
With the item of the menu tr.S. it is possible to view the memory location in which a transmitter is memorized.
To perform the function, move to tr.S. and then confirm by pressing the button MENU. Keep pressed MENU button untill the display will show
then release the button.
At this point press a button of the memorized transmitter (it does not active any command). The display shows:
•
the memory location for 2 seconds, if is memorized;
•
the written
After 2 seconds the display returns to the screen
To exit from the function, press MENU button. Otherwise after 15 seconds without transmission, the control unit exits from the function and shows the
written
tr.C. Cancellation of a single transmitter
With the item of the menu tr.C. it is possible to delete a single transmitter from the memory.
To perform the function, move to tr.C. and then confirm by pressing the button MENU. Keep pressed MENU button untill the display will show 0, then
release the button. Select the memory location of the transmitter. Press and keep pressed MENU button untill the display will show
release the button.
To exit from the function, press MENU button. If the display shows the written
position or disconnected memory).
de.f. Restore default settings
With this parameter it is possible to restore the default settings of the control unit. The reset will restore all the parameters of the base and advanced
menu, but doesn't modify the learnt strokes, the directions of motors and the transmitters.
Move to de.f. then keep pressed MENU button until the display shows 0, release the button. Press again and keep pressed MENU button, the display
will show a count down d80,d79,...,d01 ,don't release the button until the display showns
tr.f. Erasing of all transmitters
With this parameter it is possible to erase all the transmitters learnt.
Move to tr.f. then keep pressed MENU button until the display shows 0, release the button. Press again and keep pressed MENU button, the
display will show a count down d80,d79,...,d01 ,don't release the button until the display showns
7. Display and control unit state
7.1 Input LED and safety devices
6-1622241
rev.6
04/12/2018
for 2 seconds, if is not memorized.