Safety regulations prohibit the fitting
of this cooker hood over a solid fuel
stove.
The minimum safety distance
between the top of the cooker/hob
and the bottom of the cooker hood
should be at least:
- 450 mm above electric cookers
and hobs,
- 650 mm above gas cookers and
hobs,
- 650 mm above an open grill from
our range.
See "Warning and Safety instructions"
for further information.
A distance of 650 mm above electric
cookers / hobs may be preferable to
give more working space.
(Air extraction mode only)
^ If a non-return flap is not present in
the venting system, the
supplied must be fitted into the
exhaust connection in the motor unit.
The flaps must open upwards.
^ Turn the non-return flap slightly
anti-clockwise to secure it.
^ A C 100 mm or C 125 mm adapter
must be fitted to the exhaust
connection to suit the exhaust
ducting being used. Turn it slightly
anti-clockwise to secure it.
(see "Connection for air extraction").
17