Miele DA 362 EXT Panduan Pengoperasian dan Instalasi - Halaman 28
Jelajahi secara online atau unduh pdf Panduan Pengoperasian dan Instalasi untuk Kap Ventilasi Miele DA 362 EXT. Miele DA 362 EXT 32 halaman. Cooker
If the exhaust ducting is to run through
rooms, ceiling space etc. where there
may be great variations in temperature
between the different areas, the
problem of sweating or condensation
will need to be addressed. The exhaust
ducting will need to be suitably
insulated.
In addition to insulating the exhaust
ducting we recommend that a suitable
condensate trap is also installed to
collect and evaporate any condensate
which may occur.
When installing a condensate trap
ensure that it is positioned vertically
and if possible directly above the
exhaust connection.
28