Use
Filter operating hours counter
The number of hours the appliance has
been in operation is stored in memory.
The operating hours counter tells you
when the grease filter or charcoal filter
needs to be cleaned or replaced.
Resetting the operating hours
counter for the grease filter
After 30 hours of operation (or another
time if the operating hours counter has
been altered), the operating hours
indicator lamp will light up red. The
grease filter must then be cleaned.
Afterwards, the filter operating hours
counter must be reset.
^ Press the operating hours control for
about 3 seconds while the fan is
switched on.
The indicator lamp for the control will
go out.
18
Reading the operating hours counter
for the grease filter
To check the percentage of time set
already used:
^ Press the On/Off touch control to
switch the fan on.
^ Press and hold the operating hours
control in.
The indicator lamp will light up red.
One or more of the indicator lamps for
the – / + controls will flash.
The number of flashing lamps shows
the percentage of the operating time
which has already been used up.
1 lamp
= 25 %
2 lamps = 50 %
3 lamps = 75 %
4 lamps = 100 %
The number of operating hours used
remains in the memory, even when the
appliance is switched off or there is a
power cut.