Condensate trap

In addition to insulating the exhaust
duct, we recommend installing a
condensate trap to collect and
evaporate any condensate which might
accumulate.
Condensate traps are available for
exhaust ducts with a diameter of
5" (125 mm) or 6" (150 mm).
 When installing a condensate trap,
make sure that it is positioned
vertically and, if possible, directly
above the hood outlet duct collar.
The arrow on the housing indicates
the direction of airflow.

Reducing Collar

(optional accessory)
If you would like to reduce the
environmental impact of your ventilation
system by limiting the CFM output the
Reducing Collar can be installed. It
reduces the air flow to less than
400 CFM. Check local building codes
for max. CFM requirements.
 Push the Reducing Collar on the
exhaust port of the blower.
 Push the exhaust hose over it.
 Secure both with a hose clamp.