ABB ACH580-01 Series Petunjuk Manual - Halaman 2

Jelajahi secara online atau unduh pdf Petunjuk Manual untuk Peralatan Industri ABB ACH580-01 Series. ABB ACH580-01 Series 7 halaman. Base drive replacement
Juga untuk ABB ACH580-01 Series: Manual (16 halaman), Panduan Instalasi dan Start-Up Cepat (17 halaman), Petunjuk Manual (8 halaman), Panduan Instalasi dan Start-Up Cepat (17 halaman), Panduan Instalasi dan Start-Up Cepat (17 halaman)

ABB ACH580-01 Series Petunjuk Manual
REPLACEMENT INSTRUCTIONS | ACH580-01 VXR UL TYPE 1 , R2/R3/R4
Step
Instruction
1
NOTE: If needed, back-up parameters prior to disconnecting power.
Turn off source power and wait 5 minutes for the DC bus capacitors
to discharge.
Turn handle to the off position.
2
Using a T20 bit, loosen and remove two (2) M4x16 screws securing
the enclosure cover.
Save hardware.
3
Using a T20 bit, loosen and remove one (1) M4x16 screws securing
the inverter cover.
Recycle drive cover.
4
Perform voltage check to confirm no voltage is present.
NOTE: If you have control wiring connected to the Control Unit,
disconnect at this time.
Diagram
2