ABB EZClean Panduan Petunjuk Pengoperasian - Halaman 9
Jelajahi secara online atau unduh pdf Panduan Petunjuk Pengoperasian untuk Peralatan Industri ABB EZClean. ABB EZClean 16 halaman. Compressed air supply unit
E Z C L E A N | C O M P R E S S E D A I R S U P P LY U N I T | O I/ E ZC L E A N - E N R E V. A
4 Connections
Pneumatic connections
WARNING
The EZClean system develops compressed air up to a
pressure of 3.5 bar(g)/(50.7 psi(g)) maximum (when outlet
blocked [zero flow]).
• do not use compressed air for any other purpose
than that for which it is provided
• never direct a stream of compressed air towards
your body or the body of any other person
• when handling/connecting compressed air lines:
s the correct safety procedures must be observed
s suitable PPE must be worn (goggles/gloves/
overalls)
Connect the tubing to compressed air unit
Referring to Figure 5:
1 Connect one end of the 6 mm OD nylon tubing
bulkhead push-fit connector
Figure 5 Connecting 6 mm OD nylon tubing to the compressed
air unit
2 Proceed to:
• "Connect the tubing to the ABB compressed air adaptor"
to connect 6 mm OD nylon tubing to ABB compressed air
adaptor
A
to
B
.
Connect the tubing to the ABB compressed air adaptor
Referring to Figure 6:
1 Refer to the sensor accessories instructions for details on
fitting the compressed air to the probe.
2 Connect the free end of 6 mm OD nylon tubing
connector
B
on the compressed air adaptor
WARNING
Typical pressure and flow rate 1.38 bar(g) (20 psi(g))/
@ 14.16 L/min (0.5 scfm), set to perform every
4 hours.
Figure 6 Connecting 6 mm OD nylon tubing to the ABB
compressed air adaptor
3 Proceed to "Electrical connections" on page 10 to make
electrical connections.