Interfacing "Prologic" Analog Control Models with:
Jandy™ AquaLink RS, AquaSwitch, JI 2000 & Compool™
To interface the "Prologic" analog control heat pump models with the Jandy™ AquaLink RS
series or Compool, run a 2 wire (16 A.W.G. or larger) insulated cable from the device to the heat
pump. If you are using a Jandy AquaSwitch or JI2000 control use a 3 wire cable. Review wiring
diagram on page 10.
Remove the 6 screws from the heaters front service access panel and open. Look for a white,
two position wire terminal located inside the top portion of the electrical compartment and is
mounted on the rear wall. (Do not confuse it with the 4 position, white terminal block
above it !) Locate, remove and discard the orange wire loop attached at the bottom
end of this terminal. Then, attach the 2 wire cable coming from the AquaLink RS or the Compool
control to the 2 position terminal where the orange loop was prior, see page 13.
NOTE for AquaLink RS and
Compool: Turn both heater ther-
mostats all the way up and set
the mode selector switch to
pool and do not use the heater
controls as the Jandy or
Compool now has thermostat
control over the heater.
For AquaSwitch and JI2000:
The heater's thermostats still con-
trol the heater and should be
preset to the desired pool and
spa temperature. The pool/spa
select switch should be left on
pool mode and will be inactive
as the AquaSwitch or JI2000 has
switching control over the
heater.