All Figures in Chart (below right) represent Chlorinator Output in Pounds of Available Chlorine Per Day.
General Principles of Operation
e three main components of the Pulsar® 3 Chlorinator
are (from top to bottom) the briquette tank, the manifold
pool enters the Pulsar® 3 Chlorinator via the emergency
shuto
e water then splits to feed the spray
manifold then distributes the water onto the briquette bed
falls into the discharge tank and is discharged into the
discharged is determined by the ORP controller or the
Timer/Solenoid Assembly. Inlet water pressure of 17 to 45
psi is required to provide su cient flow into the Pulsar® 3.
ese pressures will result in an inlet flow of 1.6
gallons/minute.
e Pulsar® 3 feed rate settings referred to
in the Pulsar System Owners manual are calibrated for this
flow rate. Flow out of the Pulsar® 3 Chlorinator requires
vacuum to properly evacuate the discharge tank. A minimum
outlet flow-rate of 1.7 gallons/minute ensures that the flow
out of the Pulsar® 3 exceeds the flow in. Once the Pulsar® 3
has been installed the outlet flow can be measured by
watching the level in the bottom tank. If the level is
rising as the feeder is running, there is insu cient
flow out.
Operational Requirements:
Inlet pressure (Range)
d I
l a e
Outlet Vacuum
Operating Temperature
Operational Characteristics:
Inlet fl ow
Outlet fl ow (Min.)
Note: To maintain NSF approval a fl ow
indicator must be installed.
e water from the
e spray
e chlorinated solution
e amount of chlorine
SPECIFICATIONS − Model PS 5000
Dimensions:
17-45 psi
Tubing
0 3
p
i s
5-29" hg
Chlorinator diameter
40-130 F
Chlorinator height
Chlorinator weight (full)
Chlorinator weight (empty)
1.6 gpm
1.7 gpm
Capacity
62 lbs Pulsar Plus Dry Chlorinator
Briquettes (equivalent 40 lbs. available
chlorine per day)
ey Work
Pounds of Available Chlorine Per Day
Upper Timer
Knob Setting
"Normal" Bottom
Knob Setting
"Low" Bottom
Knob Setting
"High" Bottom
Knob Setting
Briquette
Hopper
Discharge
Tank
1/2" O.D.
o P
y l
t e
y h
e l
e n
19"
33"
125 lbs
27 lbs
– 1 –
A
B
C
D E
55 14 3.2 1.7 1.3 1.1 1.0
90 24 6.5 3.6 2.5 2.0 1.8
120 30 7.4 4.1 3.0 2.4 2.2
Shut-Off Valve3
Discharge
Feed Rate:
Pulsar Plus Briquettes 1.0 - 120 lbs of
Available Chlorine per day
Recommend Pool Size
10,000−4000,000 gallon unstabilized
10,000−1,500,000 gallon stabilized
Subject to local health codes.
F G
Inlet:
Emergency
Outlet: