Architectural Area Lighting MicroCore Panduan Instalasi - Halaman 4
Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Lampu luar ruangan Architectural Area Lighting MicroCore. Architectural Area Lighting MicroCore 7 halaman.
17760 ROWLAND ST.
CITY OF INDUSTRY
CALIFORNIA 91748
www.aal.net
MicroCore Upgrade Kit Installation Guide
TM
Fixture: Universe Collection Medium (UCM) (HID to LED)
4.
REMOVE TOP DOME RING
1. Remove top dome ring by unscrewing (2) 8-32 1/2in screws
as shown in Fig. 4-1 and discard the related hardware.
5.
ASSEMBLE HOOD AND RING
1. Attach the hood to the dome by (4) provided Z-brackets, (4)
previously saved 1/4-20 hex bolts and washers as shown in
Fig. 5-1.
93046644 REV. D
Tel(626)968-5666
Fax(626)968-5716
2X 8-32 1/2" SCREWS
TOP DOME RING
FIG. 4-1
4X HOOD BRACKETS
4X A84004
WSHR-1/4 INT TOOTH LK SS
4X A84051
SCR-1/4-20x1/2 BTN HD CAP SS
FIG. 5-1
PAGE 4/7
A R C H I T E C T U R A L
2. Peel off the existing gasket as shown in Fig. 4-2 and replace
with the new (provided) gasket.
HOOD RING
2. Assemble the hood ring by (4) provided 1/4-20 1/2" button
head screws and (4) washers as shown in Fig. 5-2.
A R E A
L I G H T I N G
93046018
TOP DOME GASKET
FIG. 4-2
FIG. 5-2